Square D Digest 179

Lighting Contactors

Combination Lighting Contactors, Type S

Class 8903 / Refer to Catalog 8903CT9701

www.se.com/us

Features

The features include: disconnect switch and circuit breaker versions; rugged flange mounted handle; easy installation; occupation of less space; increased operator protection; room to spare for modifications; Class R fuse clips standard; electrically and mechanically held; 30–600 A. It is desirable to install the branch-circuit protective device and lighting contactor, combining switching and over-current protection, in one enclosure. Combination lighting contactors are well suited for industrial, highway and area lighting applications, or where a lighting circuit may have to be disconnected for periodic maintenance. They may also be used for resistance heating loads. Table 16.200: Fusible or Non-Fusible Disconnect Switch—3-Pole, 50–60 Hz (replace ●●● with the voltage code)

16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS

NEMA4&4X [21] Watertight and Dusttight Enclosure Stainless Steel

NEMA12/3R [22] Dusttight, Oiltight Driptight, Industrial Use Enclosure

NEMA1 General Purpose Enclosure

Fuse Clip Size (A)

Fuse Clip Spacing (V)

Contactor Ampere Rating

Type [23]

Type [23]

Type [23]

Electrically Held [24] 30

None 30 30 None 60 60 None 100 100 None 200 200 None 400 400 None 60 60 None 100 100 None 200 200 None 400 400 30 30

— 600 250 — 600 250 — 600 250 — 600 250 — 600 250 — 600 250 — 600 250 — 600 250 — 600 250 — 600 250

SMG60●●● SMG61●●● SMG62●●● SPG60●●● SPG61●●● SPG62●●● SQG60●●● SQG61●●● SQG62●●● SVG60●●● SVG61●●● SVG62●●● SXG60●●● SXG61●●● SXG62●●● SMG70●●● SMG71●●● SMG72●●● SPG70●●● SPG71●●● SPG72●●● SQG70●●● SQG71●●● SQG72●●● SVG70●●● SVG71●●● SVG72●●● SXG70●●● SXG71●●● SXG72●●●

SMW60●●● SMW61●●● SMW62●●● SPW60●●● SPW61●●● SPW62●●● SQW60●●● SQW61●●● SQW62●●● SVW60●●● SVW61●●● SVW62●●● SXW60●●● SXW61●●● SXW62●●● SMW70●●● SMW71●●● SMW72●●● SPW70●●● SPW71●●● SPW72●●● SQW70●●● SQW71●●● SQW72●●● SVW70●●● SVW71●●● SVW72●●● SXW70●●● SXW71●●● SXW72●●●

SMA60●●● SMA61●●● SMA62●●● SPA60●●● SPA61●●● SPA62●●● SQA60●●● SQA61●●● SQA62●●● SVA60●●● SVA61●●● SVA62●●● SXA60●●● SXA61●●● SXA62●●● SMA70●●● SMA71●●● SMA72●●● SPA70●●● SPA71●●● SPA72●●● SQA70●●● SQA71●●● SQA72●●● SVA70●●● SVA71●●● SVA72●●● SXA70●●● SXA71●●● SXA72●●●

60

100

File E16151 CCNNRNT

200

NOTE: If a holding circuit contact is required for proper operation, order an additional contact.

300

Mechanically Held [24] 30 None

60

100

200

300

Table 16.202: Circuit Breaker—3-Pole, 50–60 Hz (replace ●●● with the voltage code)

Table 16.201: Coil Voltage Codes [24] Voltage

Code

NEMA4&4X [21] Watertight and Dusttight Enclosure Stainless Steel (30-300A)

60Hz 24 [25] 120 208 240 277 480 Specify

50Hz — 110 — 220 — 440 Specify

NEMA12/3R [22] Dusttight, Oiltight, Driptight, Industrial Use Enclosure

NEMA1 General Purpose Enclosure

V01 V02 V08 V03 V04 V06 V99

Circuit Breaker

Contactor Ampere Rating

Ampere Rating

Maximum Volts

Type [23]

Type [23]

Type [23]

Electrically Held [24] 30 30

600 600 600 600 600 600 600 600 600 600 600 600 600 600

SMG81●●● SPG81●●● SQG81●●● SVG81●●● SXG81●●● SYG81●●● SZG81●●● SMG91●●● SPG91●●● SQG91●●● SVG91●●● SXG91●●● SYG91●●● SZG91●●●

SMW81

SMA81●●● SPA81●●● SQA81●●● SVA81●●● SXA81●●● SYA81●●● SZA81●●● SMA91●●● SPA91●●● SQA91●●● SVA91●●● SXA91●●● SYA91●●● SZA91●●●

60

60

SPW81●●● SQW81●●● SVW81●●● SXW81●●● SYW81●●● SZW81●●● SMW91●●● SPW91●●● SQW91●●● SVW91●●● SXW91●●● SYW91●●● SZW91●●●

100 200 300 400 600

100 200 300 400 600

Mechanically Held [24] 30 30

60

60

100 200 300 400 600

100 200 300 400 600

For How to Order Information, see page page 16-28.

[21] For NEMA 4 and 4X watertight, dusttight ,and corrosion-resistant glass-polyester enclosures, add FormG18 (limited to 100 A max.). 400 and 600 A enclosures are painted sheet steel (NEMA Type 4 & 4X). [22] NEMA 12 enclosures can be field modified for outdoor non-corrosive and non–service entrance rated applications. See page 16-113 for more information. [23] Replace the three bullets (●●●) in the catalog number with the coil voltage code. Refer to the standard voltage codes shown in Table 16.197. [24] The control/coil voltage must be specified. [25] 24 V coils are not available for 200 A or larger devices. Contact the Customer Care Center for additional information.

16-78

© 2024 Schneider Electric All Rights Reserved

Made with FlippingBook Ebook Creator