Square D Digest 179

Lighting Contactors

Multipole Lighting Contactors, Type S Class 8903 / Refer to Catalog 8903CT9701

www.se.com/us

Features

• Electrically and mechanically held • 30–800 A lighting ratings • LEDready [10]

• 2- through 5-pole versions (5-poles through 200 A) • UL Listed short-circuit rating up to 100,000 Amperes • Factory wired controls and clearly marked termination points • Quick ship on most items in 5–7 days Table 16.197: Coil Voltage Codes Voltage [11]

16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS

Code

Electrically Held

60Hz 24 [12] 120 208 240 277 480 Specify

50Hz — 110 — 220 — 440 Specify

V01 V02 V08 V03 V04 [13]

V06 V99

Mechanically Held

Table 16.198: Multi-pole Lighting Contactors—Type S, 50–60 Hz (replace ●●● with the voltage code)

NEMA1 Flush Mounting General Purpose Enclosure with Plaster Adjustment

NEMA Type12/3R [16] Dusttight and Driptight Industrial Use Enclosure

NEMA4X Watertight, Dusttight and Corrosion-Resistant Glass-Polyester Enclosure

NEMA Type4X [15] Watertight and Dusttight Enclosure

NEMA Type3R Rainproof Enclosure [14]

NEMA1 General Purpose Enclosure

Contact Ampere Ratings

OpenType

No. of Poles

Type [17]

Type [17]

Type [17]

Type [17]

Type [17]

Type [17]

Type [17]

Electrically Held [11]

SMO1●●● [18] SMO2●●● [18] SMO3●●● [18] SMO4●●● [18] SPO1●●● [18] SPO2●●● [18] SPO3●●● [18] SPO4●●● [18] SQO1●●● [18] SQO2●●● [18] SQO3●●● [18] SQO4●●● [18]

2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 2 3 2 3 2 3 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 2 3 2 3 2 3

SMG1●●● SMG2●●● SMG3●●● SMG4●●● SPG1●●● SPG2●●● SPG3●●● SPG4●●● SQG1●●● SQG2●●● SQG3●●● SQG4●●● SVG1●●● SVG2●●● SVG3●●● SVG4●●● SXG1●●● SXG2●●● SYG1●●● SYG2●●● SZG1●●● SZG2●●● SJG1●●● SJG2●●● SMG10●●● SMG11●●● SMG12●●● SMG13●●● SPG10●●● SPG11●●● SPG12●●● SPG13●●● SQG10●●● SQG11●●● SQG12●●● SQG13●●● SVG10●●● SVG11●●● SVG12●●● SXG13●●● SXG14●●● SYG16●●● SYG17●●● SZG18●●● SZG19●●●

SMF1●●● SMF2●●● SMF3●●● SMF4●●● SPF1●●● SPF2●●● SPF3●●● SPF4●●● SQF1●●● SQF2●●●

SMH1●●● SMH2●●● SMH3●●● SMH4●●● SPH1●●● SPH2●●● SPH3●●● SPH4●●● SQH1●●● SQH2●●● SQH3●●● SQH4●●● SVH1●●● SVH2●●●

SMW21●●● SMW22●●● SMW23●●● SMW24●●● SPW21●●● SPW22●●● SPW23●●● SPW24●●● SQW21●●● SQW22●●●

SMW1●●● SMW2●●● SMW3●●● SMW4●●● SPW1●●● SPW2●●● SPW3●●● SPW4●●● SQW1●●● SQW2●●● SQW3●●● SQW4●●● SVW1●●● SVW2●●● SVW3●●● SVW4●●● SXW1●●● SXW2●●● SYW1●●● SYW2●●● SZW1●●● SZW2●●● SJW1●●● SJW2●●● SMW10●●● SMW11●●● SMW12●●● SMW13●●● SPW10●●● SPW11●●● SPW12●●● SPW13●●● SQW10●●● SQW11●●● SQW12●●● SQW13●●● SVW10●●● SVW11●●● SVW12●●● SXW13●●● SXW14●●● SYW16●●● SYW17●●● SZW18●●● SZW19●●●

SMA1●●● SMA2●●● SMA3●●● SMA4●●● SPA1●●● SPA2●●● SPA3●●● SPA4●●● SQA1●●● SQA2●●● SQA3●●● SQA4●●● SVA1●●● SVA2●●● SVA3●●● SVA4●●● SXA1●●● SXA2●●● SYA1●●● SYA2●●● SZA1●●● SZA2●●● SJA1●●● SJA2●●● SMA10●●● SMA11●●● SMA12●●● SMA13●●● SPA10●●● SPA11●●● SPA12●●● SPA13●●● SQA10●●● SQA11●●● SQA12●●● SQA13●●● SVA10●●● SVA11●●● SVA12●●● SXA13●●● SXA14●●● SYA16●●● SYA17●●● SZA18●●● SZA19●●●

30

60

100

— — — — — — — — — — — — — —

— — — — — — — — — — — — — —

SVO1●●● SVO2●●● SVO3●●● SVO4●●● SXO1●●● SXO2●●● SYO1●●● SYO2●●● SZO1●●● SZO2●●● SJO1●●● SJO2●●●

200

— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —

300

400 [19]

600 [19]

800 [19]

Mechanically Held [11]

SMO10●●● [18] SMO11●●● [18] SMO12●●● [18] SMO13●●● [18] SPO10●●● [18] SPO11●●● [18] SPO12●●● [18] SPO13●●● [18] SQO10●●● [18] SQO11●●● [18] SQO12●●● [18] SQO13●●● [18]

SMW31●●● SMW32●●● SMW33●●● SMW34●●● SPW31●●● SPW32●●● SPW33●●● SPW34●●● SQW31●●● SQW32●●●

SMF10●●● SMF11●●● SMF12●●● SMF13●●● SPF10●●● SPF11●●● SPF12●●● SPF13●●● SQF10●●● SQF11●●●

30

60

100

— — — — — — — — — — —

— — — — — — — — — — —

SVO10●●● SVO11●●● SVO12●●● SXO13●●● SXO14●●● SYO16●●● SYO17●●● SZO18●●● SZO19●●●

200

300

400

600

NOTE: If a holding circuit contact is required for proper operation, order an additional contact.

[10] Conforms to NEMA -410 -2015 and UL508: Table 46.1 and Section 61C test procedures for LED loads up to 16 A at 120 V. Devices were tested to 20 A at 120 V and conform to the test requirements. [11] Lighting contactors come with separate control as standard—except electrically held 400, 600, and 800 A devices, which come with common control as standard. [12] 24 V coils are not available for 200–800 A devices. Contact your local sales office for more information. [13] On 400–800 A electrically held contactors, for voltage code V04, you must select Form S (separate control). [14] Cannot support control transformer forms. [15] For contactor sizes 30–300 A, NEMA 4X enclosures are brush finished stainless steel. [16] NEMA 12 enclosures can be field modified for outdoor non-corrosive and non–service entrance rated applications. See page 16-113 for more information. [17] Replace the three bullets (●●●) in the catalog number with the coil voltage code. Refer to the standard voltage codes in Table 16.197. [18] Separate enclosures are available for these devices. It may be possible to improve delivery time by ordering an open type contactor and a separate Class 9991 enclosure from the section, Separate Enclosures, page 16-111. [19] FormFF4T comes standard; include the line voltage when ordering. Control voltage is 120–60.