Square D Digest 179
Replacement Parts
TeSys™ N Contactors and Starters
Refer to Catalog MKTED210011EN
www.se.com/us
Replacement Contacts and Coils Table 16.61: Replacement Contact Sets [29] For use on contactors Number of Poles
Catalog Number
Size3–4
3poles 3poles 3poles 3poles
LA5FF431
Size5 Size6 Size7
LA5F400803 LA5F500803 LA5F630803
Table 16.62: Size 00–1 AC Coils Rated Nominal Voltage 16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS
TeSys N Magnet Coils
Table 16.63: Size 2 AC Coils Rated Nominal Voltage V
Catalog Number 50/60 Hz
Catalog Number 50/60 Hz
24 32 42 48
LXD3B7 LXD3C7 LXD3D7 LXD3E7 LXD3K7 LXD3F7 LXD3FE7 LXD3G7 LXD3FC7 LXD3L7 LXD3LE7 LXD3M7 LXD3P7 LXD3U7 LXD3W7 LXD3Q7 LXD3V7 LXD3N7 LXD3R7 LXD3T7 LXD3S7 LXD3SC7 LXD3X7 50/60Hz
24 32 36 42 48 60
LXD1B7 LXD1C7 LXD1CC7 LXD1D7 LXD1E7 LXD1EE7 LXD1K7 LXD1F7 LXD1FE7 LXD1G7 LXD1FC7 LXD1L7 LXD1LE7 LXD1M7 LXD1P7 LXD1U7 LXD1W7 LXD1Q7 LXD1V7 LXD1N7 LXD1R7 LXD1T7 LXD1SC7 LXD1X7 50/60Hz
100 110 115 120 127 200 208 220 230 240 277 380 400 415 440 480 500 575 600
100 110 115 120 127 200 208
220/230
230
230/240
277
380/400
400 415 440 480 575 600
Specification
Specifications
Average consumption: - Inrush (inductance 0.3) - Sealed (inductance 0.3)
140 VA (inductance: 0.9) 7.5 VA (inductance: 0.9) 80–115% of nominal voltage
Average consumption - Inrush (inductance 0.75) - Sealed (inductance 0.3) Operating range@ 60 °C
70VA 7VA
Operating range at θ < 55 °C / 131 °F
50 Hz: 80–110% of nominal 60 Hz: 85–110% of nominal
Table 16.64: Size 3–7 AC Coils Contactor Size Hz Catalog Number
Catalog Number Suffix [30] 24V 48V 110V 120V 208V 220V 240V 277V 380V 415V 440V 480V 600V
Size3–4
40–400
LX9FF ● LX1FH● LX1FK●
— [31]
048
110
127
200
220
240
280
380
415
415
500
— [31]
Size5
40–400 40–400 40–400
0242
0482
1102
1272
2002 200
2202 220
2402 240
2772 280
3802 380
3802 415
4402 415
5002 415
6002 600
Size6 [32] Size7 [32]
— 048 — 048
110 110
110 110
LX1FL ●
200
220
240
260
380
415
415
415
600
Table 16.65: Size 3–4 DC Coils Device Type Catalog Number
Catalog Number Suffix [33] 24V 36V 48V
60V 060
72V 070
110V
125V
220V
250V
440V
Size3–4
LX4FF ●
024
035
048
110
125
220
250
440
[29] Provided per pole: 2 fixed contacts, 1 movable contact, 2 deflectors, 1 backplate, and the mounting screws and washers. [30] Complete the catalog number by adding the suffix (for example, LX9FF020). [31] LX1FF020 coil will be available for replacement only . [32] The 600 V coils for Sizes 6 and 7 do not include an auxiliary contact for holding circuits. If required, select the appropriate contacts from page 16-18. [33] Complete the catalog number by adding the suffix (for example, LX4FF024).
16-22
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator