Square D Digest 179
I-Line Series Ratings for I-Line Panelboards I-Line Series Connected Circuit Breaker Ratings
Refer to Catalog 2110CT9701
www.se.com/us
Table 9.145 I-Line Series Connected Circuit Breaker Ratings (RMS Symmetrical) (cont'd.) Maximum System Voltage AC [3] Maximum Short Circuit Current Rating Square D Brand Integral or Remote 2- or 3-Pole Main Circuit Breaker [4]
Square D Brand Branch Circuit Breaker
Catalog Designation
Poles
BD6 (60 A Max.)
BG6, HG, JG, LG, MG, PG
FJ
FD
FC, KC
FA, FY, FD, FG
LC, LX (400 A Max.) LC, LX (600 A Max.)
FH
FY, FD, FG
65,000
FH, FY
DJ LL LJ
9 PANELBOARDS
FY
FH, FY
BD6, BG6 (60 A Max.)
BJ, HJ, JJ, LJ, MJ, PJ
FI, KI
FH
DL, LL
FH, FJ
100,000
BD6, BG6, BJ (60 A Max.)
HL, JL, LL
FI, KI
FA, FY, FD, FG, FJ
LI, LXI, (400 A Max.) LI, LXI, (600 A Max.)
FH
200,000
FY, FD, FG, FJ
BD6, BG6, BJ (60 A Max.)
HR, JR
MG
FA FH FH KA
22,000
MX, PA, PC, PX KH, LA, MA, PJ
LA, MA, PA, PC, PX
LA,MA, PA
HD, JD
30,000
FA (25 A Max.), FH, KA
MG
MX, PA
HD, JD HD, JD FA, HD
2, 3
MH
HG, JG
JG
JD
LH, MG, PG, RG
HD, JD
35,000
BG6, HG, JG, LG, MG, PG
BD6
HG, JG
LH DG LG LG MJ RL MJ
FH, HD, JD, KA, LA, MA
LD
3
HD, JD, FH, KA, LA, MA
2, 3
FH (25 A Max.)
42,000 50,000
RG
KA, KH FA, FH
FC, KC HJ, JJ
FA, FH, HD, HG
BJ, HJ, JJ, LJ, MJ, PJ
BD6, BG6
2, 3
JD, JG
JJ
LC, LI, LX, LXI
HD, HG, JD, JG
LC, LX, (400 A Max.)
65,000
FH KA LA
480
KC, LC, LX
LC, LX
FH, HD, HG, JD, JG, KA, LA, MA
DJ LJ LJ
LD, LG
3
HD, HG, JD, JG, FH, KA, LA, MA
2, 3
HL, JL
FA, FH, HD, HG, HJ
HL, JL, LL
BD6, BG6, BJ
JD, JG, JJ
JL
LI, LXI (600 A Max.)
KA
2, 3
PC, PH, PL, RL
HJ, JJ
RL DL LL LL JR
RG
100,000
FH, HD, HG, HJ, JD, JG, JJ, KA, LA, MA HD, HG, HJ, JD, JG, JJ, FH, KA, LA, MA LD, LG, LJ
3
FA
FI, KI
FA, FH, FC, HD, HG, HJ
HR, JR
BD6, BG6, BJ JD, JG, JJ, KA
KI LI
FC, KA, KC, LA, HJ, HL, JJ, JL
200,000
KA, HJ, HL, JJ, JL FA, HD, HG, HJ, HL
LXI HR JR LR
HD, HG, HJ, HL, JD, JG, JJ, JL HJ, HL, JJ, JL, FH, LA, LH
2, 3
25,000 35,000
FH, KA
FD FD
FG, KH, LH
BG6, HG, JG, LG, MG, PG
BD6
FJ
FD
BJ, HJ, JJ, LJ, MJ, PJ
BD6, BG6
65,000
FC, KC
FD, FG FD, FG
480Y/277
LC, LX (600 A Max.)
100,000
HL, JL, LL
BD6, BG6, BJ
FI, KI
FD, FG, FJ
HR, JR
BD6, BG6, BJ
200,000
LI, LXI (600 A MAX.)
FD, FG, FJ
HG, JG
FA,HD
18,000
2, 3
600
JG
JD
[3] For indicated circuit breakers rated less than this maximum voltage. The indicated short circuit current rating also applies, but at the voltage rating of the circuit breaker. [4] LG, LJ, and LL are only available in 3-pole configurations.
9-62
© 2024 Schneider Electric All Rights Reserved