Square D Digest 179

NF Merchandised Main Lug Three Phase Interiors

NF Panelboards—600Y/347 Vac Max.

Refer to Catalog 1670CT0701

www.se.com/us

NF Main Lug Interiors - 600Y/347 Vac Max Table 9.44: NF Main Lug Interiors - Use I-Line Panelboard for 3Ø3W Delta applications above 240 Vac

Interior Only Catalog Number (Order Branch Circuit Breakers Separately) [1][3]

Water, Dirt, and Dust Resistant Enclosure Catalog Numbers [4]

NEMA 1 Enclosure Mono-Flat Trim ™ Front [7]

Mains Rating (Amps)

Circuit Breaker Pole Spaces [1] [2]

Box 20 in.Wx 5.75 in.D [5][6]

Type 3R/5/12 20 in. W x 5.75 in. D [8]

Vented Type 3R 26 in. W x 8.75 in. D [9]

Hinged Front [5]

Height (In.)

(Single Phase 3-Wire: Factory Assembled Only) Three Phase 4-Wire [10] 18 NF418L1 MH26, MH26BE

NC26( )

NC26( )HR

MH26WP

26

NF418L1C NF430L1 NF430L1C NF442L1C NF454L1C NF430L2 NF430L2C NF442L2 NF442L2C NF454L2 NF454L2C NF466L2 NF466L2C NF430L4 NF430L4C NF442L4 NF442L4C NF454L4 NF454L4C NF466L4 NF466L4C NF484L4 NF484L4C NF430L6C NF442L6C NF454L6C NF466L6C NF484L6C

NC32( ) NC38( ) NC44( ) NC38( )

NC32( )HR NC38( )HR NC44( )HR NC38( )HR

MH32, MH32BE MH38, MH38BE MH44, MH44BE MH38, MH38BE

30 42 54 30

MH32WP MH38WP MH44WP MH38WP

32 38 44 38

125

NC44( )

NC44( )HR

MH44, MH44BE

42

MH44WP

44

250

NC50( )

NC50( )HR

MH50, MH50BE

54

MH50WP

50

NC62( )

NC62( )HR

MH62, MH62BE

66

MH62WP

62

9 PANELBOARDS

NC50V( )HR

MH62D9VWP [11]

MH50, MH50BE NC50V( )

30

MH50WP

50/62

NC56V( )HR

MH68D9VWP [11]

MH56, MH56BE NC56V( )

42

MH56WP

56/68

NC62V( )HR

MH74D9VWP [11]

MH62, MH62BE NC62V( )

54

MH62WP

62/74

400

NC74V( )HR

MH86D9VWP [11]

MH74, MH74BE NC74V( )

66

74/86

MH74WP

NC86V( )HR NC50V( )HR NC56V( )HR NC62V( )HR NC74V( )HR NC86V( )HR

MH86, MH86BE NC86V( ) MH50, MH50BE NC50V( ) MH56, MH56BE NC56V( ) MH62, MH62BE NC62V( ) MH74, MH74BE NC74V( ) MH86, MH86BE NC86V( )

84 30 42 54 66 84

MH86WP

86

MH62WP [11] MH68WP [11] MH74WP [11] MH86WP [11]

MH62D9VWP [11] MH68D9VWP [11] MH74D9VWP [11] MH86D9VWP [11]

50/62 56/68 62/74 74/86

600

86

800 Factory Assembled Only [12] Note: All NF Merchandised Panelboard interiors include the following: a NFFP15 bag of blank filler plates; a neutral bonding strap; an NF information manual; a NEMA instruction booklet; and a sheet of circuit numbers.

[1] Order EDB, EGB, or EJB branch circuit breakers separately. Maximum allowable branch circuit breaker pair combination is 170 A. [2] Please note that some local building codes limit panelboards to 42 circuits, including those that reference 2005 or earlier version of the US NEC. [3] “C” suffix indicates copper bussing. [4] Wall mounting brackets add 0.4 inches to back of MHxxWP enclosures. [5] Nominal interior dimensions, see PBA600 for details. [6] If Blank End Walls are desired at both ends of NEMA 1 Enclosure, add “BE” suffix to MHXX catalog number. [7] Add “F” for flush mount, “S” for surface mount. [8] Enclosure includes trim kit. NEMA 3R, 5, 12 enclosures must be bottom fed. Nominal enclosure dimensions, see PBA555 for details. [9] Vented Type 3R enclosure with three point latch door required for outdoor applications with two sub-feed breakers, or sub-feed breaker with trip current >150A. NEMA 3R enclosures must

be bottom fed, when selected a NF12RDE kit should also be selected. Enclosure nominal dimensions, see PBA603WP for details. [10] NF panelboards without neutral connections may be applied to 3 phase, 4 wire grounded Wye systems, except at the Service Entrance. [11] NEMA 3R, 5, 12 enclosures must be bottom fed, when selected a NF12RDE kit should also be selected. [12] 800 A interiors with main circuit breaker require 8.75 inch deep, 26 inch wide enclosures.

9-23

© 2024 Schneider Electric All Rights Reserved

Made with FlippingBook Ebook Creator