Square D Digest 179
MasterPacT™ NT/NW Circuit Breakers Class 613 / Refer to Catalog 0613CT0001
MasterPacT™ Power Circuit Breakers
www.se.com/us
MasterPacT NT and NW Circuit Breakers
The MasterPacT NT and NW universal power circuit breakers offer a family of circuit protection products meeting the most common world standards, ANSI, UL and IEC. The basic design platform for each is common. The final result is UL, ANSI and IEC circuit breakers with the same basic external dimensions, features and accessories. • Complete product offering up to 200 k AIR without fuses • Circuit breakers tested to show arc flash hazard risk category as referenced by NFPA70E • 800 A to 6000 A frames, fixed and draw-out • Rated for AC voltage systems through 600 V (635 V ANSI) • Short-time withstand ratings up to 100 kA • Cradle position indicator: connected, test and disconnected • Simple, visual contact wear indicators • Full complement of field-installable accessories common to all standards • Four interchangeable MicroLogic trip units to choose from • Available PowerLogic™ based power metering and monitoring capabilities • Available protective relay functions as defined by ANSI C37.2 and C37.90 The following charts show the MasterPacT NW and NT ratings for ANSI and UL 489. See the Catalog 0613CT0001 .
MasterPacT NT
MasterPacT NW
Table 7.146: MasterPacT NW Circuit Breaker Ratings
ANSI C37 Certified/UL 1066 Listed
UL 489 Listed
4000/ 5000/ 6000A
Standard Frame Rating Interrupting Code
3200/4000 A [9]
800–1600A
2000A
4000/5000 A 800/1200/1600/2000 A 2500/ 3000A
L1 [10]
L1F [10] H1 H2 H3
L1 [10]
L1F [10] H1 H2 H3
L1 [10] H2 H3
L1 [10]
L [10]
LF [10]
L [10]
L [10]
N1 H1 H2 H3
N H
H
H
Interrupting Current (kARMS) 50/60Hz 240 Vac 42 65 85 100 200 200 65 85 100 200 200 65 85 100 200 85 100 200 65 100 200 200 100 200 100 200 480 Vac 42 65 85 100 200 200 65 85 100 200 200 65 85 100 200 85 100 200 65 100 150 150 100 150 100 150 600 Vac 42 65 85 85 130 130 65 85 85 130 130 65 85 85 130 85 85 130 50 85 100 100 85 100 85 100 Short-time Withstand Current (kA RMS) 42 65 85 85 30 22 65 85 85 30 22 65 85 85 100 85 85 100 42 [11] 65 [11] 30 22 65 65 85 100
[11] [12] [11] [12]
Built-in Instantaneous Override (kA RMS ±10%) Close and latch rating (kA RMS) Tested to show arc flash hazard risk category as referenced by NFPA70E
35 [13] 24 — — 85 35 24 — — 85117— —11740 40 35
35 [13]
35 [13]
35 [13]
85
24 65 65 75 75
42 65 40 40 25 22 65 40 40 25 22 65 40 40 40 85 75 40 40 40 25 [14]
22 40 40 40 40
—————Yes————Yes——————————Yes————
Breaking time Closing time
25–30 ms with no intentional delay (9 ms for L1, L1F, L and LF)
70ms
2000– 4000A 2500– 5000A 3000– 6000A 5,000
100–250A 400–800A 600–1200A 800–1600A 1000–2000 A 12,500 [15]
1200– 2500A 1600– 3000A
100–250A 400–800A 800–1600A
2000–4000 A 2500–5000 A
Sensor Rating
1000–2000 A
1600–3200 A
Endurance Rating (C/O
12,500
10,000
10,000
5,000
10,000
Mechanical
5k
Cycles) WithNo Mainte nance
2800 [15]
1,000
1,000
1,000
1,000
1,000
Electrical
2800
1k
[9] 4000 A standard width circuit breaker is not available in L1 interrupting rating code or drawout construction (fixed mounting only). [10] Drawout mounted only. [11] 24 kA RMS for 800 A circuit breaker frame with 100 A or 250 A sensor. [12] 65 kA RMS for 2000 A. [13] None except 24 kA RMS for 800 A circuit breaker frame with 100 A or 250 A sensor. [14] 40 kA RMS for 2000 A. [15] The endurance rating for 2000 A, N/H/L/LF is 10,000 for mechanical and 1000 for electrical.
CIRCUIT BREAKERS
7 MINIATURE AND MOLDED CASE
7-77
© 2024 Schneider Electric All Rights Reserved