Square D Digest 179
MiCOM Protection Relays
MiCOM Railway Applications
www.se.com/us
MiCOM Railway Applications
Easergy™ MiCOM P138 - Overcurrent Protection Device for Rail Applications The Easergy MiCOM 30 series rail devices are dedicated to railway catenary protection. The Easergy MiCOM P138 specifically provides directional overcurrent protection for rail applications The Easergy MiCOM P138 enables a wide range of applications to protect supplies and catenaries in classic and autotransformer-fed (AT) systems. With easy connection to virtually all substation and catenary network management systems, it is enhanced by a complete range of backup protection and automation functions Easergy MiCOM P638 - Transformer Protection Device for Rail Applications Easergy MiCOM Px30 rail devices are dedicated to railway catenary protection. The Easergy MiCOM P638 provides transformer differential protection Easergy MiCOM P638 enables a wide range of applications to protect supplies and catenaries in classic and autotransformer-fed (AT) systems. With easy connection to virtually all substation and catenary network management systems, Easergy MiCOM P638 is enhanced by a complete range of backup protection and automation functions Easergy MiCOM P436 and P438 - Distance Protection Devices for Rail Applications Easergy MiCOM 30 series rail devices are dedicated to railway catenary protection. The Easergy MiCOM P436 provides catenary protection for classic and two-phase AT feeders. Easergy MiCOM P436 and Easergy MiCOM P438 enable a wide range of applications to protect supplies and catenaries in classic and autotransformer-fed (AT) systems. With easy connection to virtually all substation and catenary network management systems, the two models are enhanced by a complete range of backup protection and automation functions.
P138 / P436 / P438
Table 5.53: Functions available for the different models of the Railway protection MiCOM range of relays ANSI Protection Function P138 P436 P438
P638
21/21N 27/59
Distance
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Over / under voltage Thermal overload Switch on-to fault High current supervision Phase overcurrent Circuit breaker failure Phase directional Under / over frequency
● ● ● ● ● ● ● ● ● ●
● ●
49
50/27
50H
50/51N 50/51P 62/50BF
High current ground fault (tank protection)
● ● ● ● ● ● 2
67P
81 86
87T 5 PROTECTION, CONTROL, AND ENERGYAUTOMATION di/dt,dv/dt, dΦ /dt Hz TCS CTS VTS
Lock-out
Transformer differential (windings)
Train startup detection Rail catenary protection Trip circuit supervision
162/3
25/50/60
●
●
Current transformer supervision Voltage transformer supervision
● ● ● ● ● ●
2nd harmonic restraint
●
3rd, 5th, 7th harmonic blocking
Defrost protection
High impedance fault detection
InterMiCOM
Table 5.54: Typical Catalog Numbers Catalog Numbers Descriptions P138849011M0303409612947
Series 30, Feeder relay, 60-250 Vdc/100-230 Vac with 4 high break contact plus 10 inputs and 16 outputs , 61850 Series 30, Distance relay, 60-250 Vdc/100-230 Vac with 4 high break contact plus 10 inputs and 16 outputs , 61850 Series 30, Transformer Relay, 60-250 Vdc/100-230 Vac with 4 high break contact plus 10 inputs and 16 outputs , 61850
P438849020M0308417616947 P638849011M0303406612947
5-30
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator