Square D Digest 179
QO™ Load Centers
QO Load Centers, Rainproof, Single Phase
Class 1130 / Refer to Catalog 1100CT0501
www.se.com/us
1 LOAD CENTERS
QO Load Centers with Included Cover 1Ø3W—120/240 Vac Indoor—UL Listed Table 1.23: Load Centers with Included Cover (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) Mains Rating Short Circuit Current Rating Spaces Max. 1P Circuits [16] Max. Tandem Circuit Breakers Load Center [17] Box, Interior, and Cover Al Cu Bus Rating Equipment Ground Bar Kit BoxNo. [18]
PKGTALP1 Included PKGTALP1 Included PK15GTA, LK100AN Included PK23GTA, LK100AN Included PK23GTA, LK100AN Included PK23GTA, LK100AN Included PK9GTA PK9GTA PK9GTA PK15GTA PK15GTA PK18GTA PK15GTA PK23GTA PK18GTA PK23GTA
QO112L125PGC
5
65kA
12
24
12
6-2/0
125
QO120L125PGC OBS
65kA
20
24
4
6-2/0
125
6
125A
QO124L125PGC
65kA
24
34
10
6-2/0
125
7
Convertible Mains—Factory-Installed Main Lugs [19] —QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-3)—Copper Bus 200A 65kA 30 40 10 QO130L200PGC 4-250 225
9
QO142L225PGC
65kA
42
52
10
4-300
225
11
225A
QO154L225PGC OBS
65kA
54
72
18
4-300
225
12
Convertible Mains—Factory-Installed Main Circuit Breaker— QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-25 or Lower Amperage Main Circuit Breaker (See page 1-3)—Copper Bus [8][20]
QO112M100PC QO116M100PC OBS QO120M100PC QO124M100PC
22kA 22kA 22kA 22kA
12 16 20 24
24 24 24 34
12
6–2/0 6–2/0 6–2/0
6–1 6–1 6–1
125 125 125 125
5 6 6 7
8 4
100A
10
4-300
Convertible Mains—Factory-Installed Main Circuit Breaker— QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-25 or Lower Amperage Main Circuit Breaker (See page 1-3)—Copper Bus [8][20] 150A 22kA 30 40 10 QO130M150PC 4-250 225
9
QO142M150PC QO130M200PC QO140M200PC QO142M200PC QO154M200PC
22kA 22kA 22kA 22kA 22kA
42 30 40 42 54
52 40 60 52 72
10 10 20 10 18
4-300 4-250 4-300 4-300
225 225 225 225 225
11
9
4-300
4-250
10 11 12
200A
OBS This product is obsolete.
Plug–on Neutral Load Center Main Lugs, Convertible Mains 1Ø3W—120/240 Vac Rainproof—UL Listed QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plug on Neutral connection on every unit. Table 1.24: Convertible Main Lugs Plug-on Neutral Load Center (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) Mains Rating Spaces Max. Load Center Box and Interior Al Cu Bus Rating Equipment Ground Bar Kit (Factory Included) BoxNo. [21] Single Pole Circuits [16]
Max. Tandem Circuit Breakers
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating [22][19][23] QOM1 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included
R A I N P R O O F
QO112L125PGRB QO116L125PGRB QO124L125PGRB
12 16 24
24 24 34
12
6–2/0 6–2/0 6–2/0
125 125 125
PKGTALP1 PKGTALP1 PK15GTA
3R 4R 4R
125A
8
10
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating [22][19][23] QOM2 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included
QO112L200PGRB QO130L200PGRB QO140L200PGRB QO142L225PGRB
4–300
4–250
225 225 225 225
PKGTALP1 PK23GTAL PKGTALP2
5R 6R 7R 8R
12 30 40 42
24 40 60 52
12 10 20 10
200A
4–250
4–300
4–250
PK23GTA, LK100AN
225A
4–300
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
[16] Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. [17] Order F for flush device or S for surface device. [18] See page 1-34 [19] UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. [20] [9] 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. [21] See Enclosure Dimensions, page 1-36 or Indoor Enclosure Dimensions and Knockout Information, page 1-34 [22] UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. [23] Side hinge door device; allow 1-1/4 in. on left side for door to open.
1-12