Square D Digest 179
QO™ Load Centers
QO Indoor Load Centers, Single Phase Class 736, 1130 / Refer to Catalog 1100CT0501
www.se.com/us
1 LOAD CENTERS
Plug-on Neutral Load Center Main Breaker, Convertible Mains 1Ø3W—120/240 Vac Indoor—UL Listed QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plug on Neutral connection on every unit. Table 1.20: Convertible Main Breaker Plug-on Neutral Load Centers (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers)
Equipment GroundBar Kit (Order Separately)
Load Center Covers
Max. 1P Circuits
Max. Tandem Breakers
Mains Rating
Bus Rating
Box No. [8]
Space s
Load Center Box and Interior
Al
Cu
Flush/Surface
Mono-Flat
Convertible Mains — Factory-Installed Main Circuit Breaker— 22 kA Short Circuit Current Rating Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (see QO Standard Plug-On Circuit Breakers, page 1-3) [9] , QOM1 Main Circuit Breaker Frame Size—Copper Bus
QOC12UF QOC12US
QO112M100P
12
24
12
—
6-2/0 6–1
125
PK9GTA
5
QO116M100P QOC20U100F [10] QOC200U100S QO120M100P QOC20U100F [10] QOC200U100S QO124M100P QOC24UF [10] QOC24US QO132M100P QOC32UF [10] QO124M125P QOC24UF [10] QOC24US QO132M125P QOC32UF [10] QO124M150P QOC30UF [10] QOC30US QO130M150P QOC30UF [10] QOC30US QO132M150P QOC40UF [10] QOC40US QO124M200P QOC30UF [10] QOC30US QO130M200P QOC30UF [10] QOC30US QO140M200P QOC40UF [10] QOC40US QO142M200P QOC42UF [10] QOC42US QO154M200P QOC54UF [10] QOC30UF [10] QOC30US QOC30UF [10] QOC30US
16
24
8
—
6-2/0 6–1
125
PK9GTA
6
100A
20
24
4
—
6-2/0 6–1
125
PK9GTA
6
24 32 24 32
34 38 34 38
10
— — — —
6-2/0 6-2/0 6-2/0 6-2/0
125 125 125 125
PK15GTA 7 PK15GTA 8 PK15GTA 7 PK15GTA 8
6
10
125A
6
Convertible Mains — Factory-Installed Main Circuit Breaker— 22 kA Short Circuit Current Rating Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (see QO Standard Plug-On Circuit Breakers, page 1-3) [9] , QOM2 Main Circuit Breaker Frame Size—Copper Bus
QOCMF30UCW [10]
20
30
10 QO120M150P OBS
4-250
225
PK15GTA 9
I N D O O R
QOCMF30UCW [10]
24
36
12
4-250
225
PK15GTA 9
150A
QOCMF30UCW [10]
4-250
225
PK15GTA 9
30
40
10
32
40
10
—
4-300
4-250 225
PK15GTA 10
QOCMF30UCW [10]
20
30
10 QO120M200P OBS
4-300
4-250 225
PK15GTA 9
QOCMF30UCW [10]
4-300
4-250 225
PK15GTA 9
24
36
12
QO154M200P
QOCMF30UCW [10]
30
40
10
4-250
225
PK15GTA 9
200A
40
60
20
—
4-300
4-250 225
PK23GTA 10
QOCMF42UCW [10] QOCMF54UCW [10]
4-300 4-300 4-300
225 225 225
PK18GTA 11 PK23GTA 12 PK27GTA 24
42 54 60
52 72 72
10 18 12
QO160M200PC [11]
—
—
QOC42UF [10] QOC42US
QOCMF42UCW [10]
40
60
20 QO140M225P OBS
4-300
225
PK23GTA 11
225A
QO142M225P QOC42UF [10] QOC42US
QOCMF42UCW [10]
4-300
225
PK18GTA 11
42
52
10
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. OBS This product is obsolete.
Field-Installed Main Lugs Kits, 1Ø
Table 1.21: 1Ø Field-Installed Main Lug Kits—Use with Convertible Main Load Centers Only
Useon Convertible Load Center with Mains Rating
Lug Wire Size [13] AWG/kcmil Al orCu
MainLugs Rating [12]
Cat. No.
QOL125 [14]
125A 125A 225A
100–125A 100–125A 150–225A
6–2/0 6–4/0 6–300
QOL125VD [14]
QOL225 [14]
QOL125
QOL225
[8] See Indoor Knockout Information and Enclosure Dimensions, page 1-34. [9] 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. [10] Available in gray and white. For white equivalencies, add the “W” suffix to the reference, or see page 1-29. [11] For Certification to IEC 60439-1 contact the local Square D sales office; otherwise panels are NOT CE marked. (For use on 415Y/240 Vac 3-phase 4-wire, 3,000 Short Circuit Current Rating when QOXD...branch circuit breakers are used and 10,000 Short Circuit Current Rating when QO...VS branch circuit breakers are used). [12] Do not exceed the load center mains rating. [13] Wire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular load center per UL, see Main Wire Size in that load center table. [14] If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from Table 1.51, page 1-25
1-10
© 2024 Schneider Electric All Rights Reserved