SE Modicon M580 Brochure
Modicon M580 automation platform Architectures Safety I/O architectures
Overview (continued)
Modicon M580 architecture type
Integrated Safety architecture
Common Safety architecture
Safety high-availability architectures (primary and redundant CPU)
1
1
Local I/O
Safe and non-safe local I/O
Safe and non-safe remote I/O over Ethernet
Remote I/O over Ethernet Non-safe distributed I/O
Safe and non-safe remote I/O over Ethernet Non-safe distributed I/O
Hot Standby topology with devices available on distributed and remote I/O over Ethernet
Separation between Safe and non-Safe ePAC
Unique ePAC for Safe and non-Safe
Integrated or Common Safety
2
2
3
3
4
4
Expansion rack (with X-bus rack expansion module)
Main local rack with up to 7 local expansion racks on X-bus (Modicon X80 racks), RIO drop with up to 1 remote expansion rack on X-bus (only Modicon X80 racks)
No local I/O on high-availability architecture
Backplane compatibility BMEXBP pp 00 Ethernet + X-bus backplanes
Compatible for main racks (local or remote)
Compatible for main racks (remote only)
BMXXBP pp 00 X-bus backplanes PV02 (or later)
Mandatory for expansion racks (main or remote) Compatible with any rack provided that no Modicon X80 I/O Ethernet modules (such as weighing, HART, and BMECRA31210 modules) are used in the racks
Compatible CPU types CPU Ethernet ports
All Safety standalone processors are compatible
All Safety redundant processors are compatible
5
5
SERVICE port
One SERVICE port for HMI, EcoStruxure Control Expert (1) , control network, variable speed drive, etc.
Dual ports are used for remote equipment (RIO scanner), BMECRA31210 Ethernet drop adapter is mandatory in RIO drop (2)
Dual port
RIO drops
A maximum of 31 RIO drops can be supported in an M580 network
Communication
AS-Interface module
BMXEIA0100
Yes, in a local rack or RIO drop Yes, in a local rack or RIO drop
6
6
Serial link module
BMXNOM0200
RTU module
BMENOR2200H BMENOP0300 BMENUA0100
Yes, only in a local rack Yes, only in a local rack Yes, only in a local rack Yes, only in a local rack
IEC 61850 module
OPC UA module
Ethernet communication modules BMENOC03 p 1
7
7
CANopen module
BMECXM0100 PMEPXM0100
No
PROFIBUS DP Master module
Yes
Yes, only in local rack
Expert functions
PTO (pulse train output) module BMXMSP0200
Yes, only in a local rack
No
Other expert modules: counter, SSI encoder, etc.
Yes, in a local rack or RIO drop Yes, in a local rack or RIO drop
Yes, in RIO drop Yes, in RIO drop
Time stamping
1 ms max. between modules in the same rack as ERT time stamping module 10 ms with CRA I/O drop adapter combined with discrete I/O modules in the RIO drop
BMXERT1604T
8
8
BMECRA31210
Yes, only in the RIO drop, system mode with OFS (2)
Pages
5/23
5/23
5/23
(1) Unity Pro software in earlier versions. (2) BMXCRA31210 module is also compatible.
9
9
10
10
More technical Information on www.se.com
More technical Information on www.se.com
5/6
5/7
Made with FlippingBook flipbook maker