SE Modicon M580 Brochure

Modicon M580 automation platform Architectures Safety I/O architectures

Overview (continued)

Modicon M580 architecture type

Integrated Safety architecture

Common Safety architecture

Safety high-availability architectures (primary and redundant CPU)

1

1

Local I/O

Safe and non-safe local I/O

Safe and non-safe remote I/O over Ethernet

Remote I/O over Ethernet Non-safe distributed I/O

Safe and non-safe remote I/O over Ethernet Non-safe distributed I/O

Hot Standby topology with devices available on distributed and remote I/O over Ethernet

Separation between Safe and non-Safe ePAC

Unique ePAC for Safe and non-Safe

Integrated or Common Safety

2

2

3

3

4

4

Expansion rack (with X-bus rack expansion module)

Main local rack with up to 7 local expansion racks on X-bus (Modicon X80 racks), RIO drop with up to 1 remote expansion rack on X-bus (only Modicon X80 racks)

No local I/O on high-availability architecture

Backplane compatibility BMEXBP pp 00 Ethernet + X-bus backplanes

Compatible for main racks (local or remote)

Compatible for main racks (remote only)

BMXXBP pp 00 X-bus backplanes PV02 (or later)

Mandatory for expansion racks (main or remote) Compatible with any rack provided that no Modicon X80 I/O Ethernet modules (such as weighing, HART, and BMECRA31210 modules) are used in the racks

Compatible CPU types CPU Ethernet ports

All Safety standalone processors are compatible

All Safety redundant processors are compatible

5

5

SERVICE port

One SERVICE port for HMI, EcoStruxure Control Expert (1) , control network, variable speed drive, etc.

Dual ports are used for remote equipment (RIO scanner), BMECRA31210 Ethernet drop adapter is mandatory in RIO drop (2)

Dual port

RIO drops

A maximum of 31 RIO drops can be supported in an M580 network

Communication

AS-Interface module

BMXEIA0100

Yes, in a local rack or RIO drop Yes, in a local rack or RIO drop

6

6

Serial link module

BMXNOM0200

RTU module

BMENOR2200H BMENOP0300 BMENUA0100

Yes, only in a local rack Yes, only in a local rack Yes, only in a local rack Yes, only in a local rack

IEC 61850 module

OPC UA module

Ethernet communication modules BMENOC03 p 1

7

7

CANopen module

BMECXM0100 PMEPXM0100

No

PROFIBUS DP Master module

Yes

Yes, only in local rack

Expert functions

PTO (pulse train output) module BMXMSP0200

Yes, only in a local rack

No

Other expert modules: counter, SSI encoder, etc.

Yes, in a local rack or RIO drop Yes, in a local rack or RIO drop

Yes, in RIO drop Yes, in RIO drop

Time stamping

1 ms max. between modules in the same rack as ERT time stamping module 10 ms with CRA I/O drop adapter combined with discrete I/O modules in the RIO drop

BMXERT1604T

8

8

BMECRA31210

Yes, only in the RIO drop, system mode with OFS (2)

Pages

5/23

5/23

5/23

(1) Unity Pro software in earlier versions. (2) BMXCRA31210 module is also compatible.

9

9

10

10

More technical Information on www.se.com

More technical Information on www.se.com

5/6

5/7

Made with FlippingBook flipbook maker