QMark Catalog 2024-2025
MUH SERIES Unit Heater
UNIT HEATERS
Optional Accessories:
3–20 kW 25–50 kW
A 7 1/4 " B 9 1/2 " C 7 1/4 " D 11 5/16 " E 2 1/4 " L 20 1/2 " M 9 15/16 " N 3 1/4 "
9 7/16 " 14 3/8 " 12 1/8 "
2 1/16 "
3"
28 15/16 " 14 15/16 "
4 1/2 "
UNIT HEATERS
MUH PRO SERIES UNIT HEATER
Optional Mounting Brackets:
Optional Field-Installed Electrical Controls:
CATALOG NO. UPC
COMPATIBILITY SHIP WT.*
CATALOG NO. UPC
DESCRIPTION
ELECTRICAL RATING
8 lbs
B10
685360152295
MUH03–10
Single Pole Internal Thermostat Temp Range: 40°- 85°F Two Stage Internal Thermostat Temp. Range: 40°- 85°F
25A @ 120, 240VAC Res. 22A @ 277VAC Res. 25A @ 120, 240VAC Res. 22A @ 277VAC Res. 125VA
UHMT1
685360152417
MCB105PK 685360173627
(Master Pack, Five B10 Brackets)
10 lbs
UHMT2
685360152424
B20
685360152301
MUH15 & 20
13 lbs
B30
685360152318
MUH25 & 30
Internal Summer Fan Switch 250, 480, 600V.A.C. 1,2 OR 3 PH
Pilot Duty 6A, 600VAC Res. 2 HP
Standard
MCFS
685360046372
15 lbs
B50
685360152325
MUH40 & 50
Remote Summer Fan Switch (Line Voltage) Remote Summer Fan Switch with Relay (24V Coil-Single Pole Normally Open) Heat Recovery Thermostat with Relay (24V Coil-Single Pole Normally Open) i - 120°F, Low - 60°F
MRFS1
685360047089
2 HP, 250-480VAC
3 lbs
CMB10
685360152363
MUH03–10
4 lbs
CMB20
685360152370
MUH15 & 20
6 AFL, 35 ALR, 250VAC, 60Hz. 3 AFL, 18 ALR, 480VAC, 60Hz 6 AFL, 35 ALR, 250VAC, 60Hz 3 AFL, 18 ALR, 480VAC, 60Hz
MRFS2
685360047096
5 lbs
CMB30
685360152387
MUH25 & 30
Ceiling
6 lbs
CMB50
685360152394
MUH40 &50
Introducing the MUH PRO series Unit Heaters. Same great MUH you rely on everyday but now with added safety and control. The new MUH Pro series comes standard with: n A disconnect switch to make maintenance a safe and easy process. n A 24VAC transformer for safer control as well as future proofing in case a low voltage digital thermostat is desired in the future. n A built in single stage thermostat which gives basic control right out of the box. n PRO-SSP Models come with the SmartSeries Plus ready to be remote mounted, to give you BMS communication via BACnet MS/TP, digital touchscreen, 7 day schedule, temporary override or setback, and cooling mode to run only the fan. Benefits of the MUH PRO: n Safety : The integrated disconnect switch and low voltage transformer add additional safety to the base MUH lineup. The disconnect switch gives peace of mind to the maintenance worker because the disconnect switch will cutoff incoming power to the unit so it can be easily repaired. The low voltage transformer no longer requires you to work with line voltage control for easy and safer control. n Better Lead Times : The MUH PRO series heater will be a stock product so they will have the same lead times as the base MUH models we have today meaning no long wait for configured units! n Better Pricing : Enjoy the benefits of the three added accessories without the full cost of a similar configured style unit. n Easy Setup : All of the accessories are installed in the factory so once the product reaches your door it just needs to be wired then set via the built in thermostat and you are good to go. 5 lbs 7 lbs 9 lbs 5 lbs 6 lbs 10 lbs MHRT 685360046945 MPDS25 685360047034 Power Disconnect Switch (3-Pole) MPDS60 685360047041 Power Disconnect Switch (3-Pole) No Diffuser: No diffuser eeded where a straight downflow air pattern is required. For maximum air throw, remove louvers. Any of three diffusers can be added to basic heat r. Louver Diffuser: Permits directi n l (s ight line) air flow as in air curtai application over doorways. Rectangular coverage, Louvers can be turned in either direction. NOTE: Visit website or contact your local representative for additional details
VDMB5
685360152455
MUH03–05
VDMB20
685360152462
MUH07–20
IDEAL SPACES § Factories § Warehouses § Garages § Stairwells § Shipping Docks § Power Stations § Mechanical Rooms MOUNTING LIMITATIONS: Unit heaters should not be used in potentially explosive atmospheres. The finish is not intended for direct salt spray exposure in marine applications or the highly corrosive atmospheres of swimming pools, chemical storage bins, etc. Do not install unit heaters above recommended maximum mounting height. Obstructions must not block unit heater air inlet or discharge. Heaters must be mounted at least 7 ft. above the floor to prevent accidental contact with the heating element or fan blade which could cause injury. Optional Dust Shields: Vertical Ceiling VDMB50 685360152479 MUH25–50
30A @ 600VAC, Res.
80A @ 600VAC, Res.
NOTE: Any field installed options assembled in the factory require added surcharge. See price book for charges. MPDS60 disconnect switch is not suitable for field installation on 7.5kw and 10kw unit heaters. Visit website or contact your local representative for compatibility details. Diffusers for Vertical Mounting:
COLORS § Neutral Gray/Statuary Bronze DIMENSIONS § Varies (see diagram) TEMP RANGE § 40°– 90°F CFM § 350 – 650 UPC 685360150697 685360150673
CATALOG NO.
COMPATIBILITY SHIP WT.*
JRDS8
3–5 KW units
JRDS14
15–20 KW units
JRDS19
685360150680 25–50 KW units
Now compatible with SmartSeries Plus when used with 24VAC control transformer!
Now compatible with SmartSeries Plus when used with 24VAC control transformer!
Suggested Controls
5
1 Y E A R WARRANTY WORKMANSHIP
Y E A R WARRANTY
For more information visit MarleyMEP.com/Products/Unit-Garage-Heaters n Easily Stocked : With all the features and product built as a stock it is easy to keep on the shelves of distributors so you can get the product right when you need it.
E L E M E N T
46 | Unit Heaters
rev: Jul 2022
Made with FlippingBook. PDF to flipbook with ease