QMark Catalog 2024-2025
MUH SERIES Unit Heater
UNIT HEATERS MARLEY CUSTOM CAPABILITIES
Optional Accessories:
3–20 kW 25–50 kW
A 7 1/4 " B 9 1/2 " C 7 1/4 " D 11 5/16 " E 2 1/4 " L 20 1/2 " M 9 15/16 " N 3 1/4 "
9 7/16 " 14 3/8 " 12 1/8 "
2 1/16 "
3"
28 15/16 " 14 15/16 "
4 1/2 "
Optional Mounting Brackets:
Optional Field-Installed Electrical Controls:
CATALOG NO. UPC
COMPATIBILITY SHIP WT.*
CATALOG NO. UPC
DESCRIPTION
ELECTRICAL RATING
U
8 lbs
B10
685360152295
MUH03–10
Single Pole Internal Thermostat Temp Range: 40°- 85°F Two Stage Internal Thermostat Temp. Range: 40°- 85°F
25A @ 120, 240VAC Res. 22A @ 277VAC Res. 25A @ 120, 240VAC Res. 22A @ 277VAC Res. 125VA
UHMT1
685360152417
MCB105PK 685360173627
(Master Pack, Five B10 Brackets)
MUH PRO SERIES UNIT HEATER 685360152424
10 lbs
UHMT2
B20
685360152301
MUH15 & 20
13 lbs
B30
685360152318
MUH25 & 30
Internal Summer Fan Switch 250, 480, 600V.A.C. 1,2 OR 3 PH
Pilot Duty 6A, 600VAC Res. 2 HP
Standard
MCFS
685360046372
15 lbs
B50
685360152325
MUH40 & 50
Remote Summer Fan Switch (Line Voltage) Remote Summer Fan Switch with Relay (24V Coil-Single Pole Normally Open) Heat Recovery Thermostat with Relay (24V Coil-Single Pole Normally Open) Hi - 120°F, Low - 60°F
MRFS1
685360047089
2 HP, 250-480VAC
3 lbs
CMB10
685360152363
MUH03–10
4 lbs
CMB20
685360152370
MUH15 & 20
6 AFL, 35 ALR, 250VAC, 60Hz. 3 AFL, 18 ALR, 480VAC, 60Hz 6 AFL, 35 ALR, 250VAC, 60Hz 3 AFL, 18 ALR, 480VAC, 60Hz
MRFS2
685360047096
5 lbs
CMB30
685360152387
MUH25 & 30
Ceiling
6 lbs
CMB50
685360152394
MUH40 &50
MHRT
685360046945
5 lbs
VDMB5
685360152455
MUH03–05
7 lbs
VDMB20
685360152462
MUH07–20
Power Disconnect Switch (3-Pole) Power Disconnect Switch (3-Pole)
MPDS25
685360047034
30A @ 600VAC, Res.
9 lbs
VDMB50
685360152479
MUH25–50
Ceiling
Vertical
MOUNTING LIMITATIONS: Unit heaters should not be used in potentially explosive atmospheres. The finish is not intended for direct salt spray exposure in marine applications or the highly corrosive atmospheres of swimming pools, chemical storage bins, etc. Do not install unit heaters above recommended maximum mounting height. Obstructions must not block unit heater air inlet or discharge. Heaters must be mounted at least 7 ft. above the floor to prevent accidental contact with the heating element or fan blade which could cause injury. Optional Dust Shields:
MPDS60
685360047041
80A @ 600VAC, Res.
Introducing the MUH PRO series Unit Heat on everyday but now with added safety an series comes standard with: n A disconnect switch to make maintenan n A 24VAC transformer for safer control as a low voltage digital thermostat is desire n A built in single stage thermostat which the box. n PRO-SSP Models come with the Smart mounted, to give you BMS communicat touchscreen, 7 day schedule, temporary cooling mode to run only the fan. Benefits of the MUH PRO: n Safety : The integrated disconnect switc add additional safety to the base MUH l switch gives peace of mind to the maint disconnect switch will cutoff incoming p easily repaired. The low voltage transfor work with line voltage control for easy a n Better Lead Times : The MUH PRO ser product so they will have the same lead models we have today meaning no long n Better Pricing : Enjoy the benefits of the without the full cost of a similar configur n Easy Setup : All of the accessories are in the product reaches your door it just ne built in thermostat and you are good to n Easily Stocked : With all the features an easy to keep on the shelves of distributo right when you need it.
IDEAL SPACES § Factories § Warehouses § Garages § Stairwells NOTE: Any field installed options assembled in the factory require added surcharge. See price book for charges. MPDS60 disconnect switch is not suitable for field installation on 7.5kw and 10kw unit heaters. Visit website or contact your local representative for compatibility details. Diffusers for Vertical Mounting: No Diffuser: § Shipping Docks § Power Stations § Mechanical Rooms
CATALOG NO.
UPC
COMPATIBILITY SHIP WT.*
COLORS § Neutral Gray/Statuary Bronze DIMENSIONS § Varies (see diagram) TEMP RANGE § 40°– 90°F CFM § 350 – 650 No diffuser needed where a straight downflow air pattern is required. For maximum air throw, remove louvers. Any of three diffusers can be added to basic heater. Louver Diffuser: Permits directional (straight line) air flow as in air curtain application over doorways. Rectangular coverage, Louvers can be turned in either direction. NOTE: Visit website or contact your local representative for additional details
5 lbs
JRDS8
685360150697
3–5 KW units
6 lbs
JRDS14
685360150673
15–20 KW units
10 lbs
JRDS19
685360150680 25–50 KW units
Optional Factory-Installed Controls & Accessories:
DESCRIPTION
MUH03 & 05 (208, 208/240, 277V Supply) 24 or 120V Control Transformer and Power Contactor 24 or 120V H.C. Power Contactor
MUH03 & 05 (480V Supply) & MUH07 through MUH50 Optional 120V Control
2-Stage Control of Elements
Now compatible with SmartSeries Plus when used with 24VAC control transformer! Now compatible with SmartSeri s Plus when used with 24VAC control transformer!
Manual Reset
Outlet Mesh (Bird Screen) For all HUHAA Heaters
NOTE: Any factory-installed options require added surcharge. See price book for charges or contact factory.
Suggested Controls
5
1 Y E A R WARRANTY WORKMANSHIP
Y E A R WARRANTY
E L E M E N T
122 | Unit Heaters
For more information visit MarleyMEP.com/Products/Unit-Garage-Heaters
rev: Jul 2022
Made with FlippingBook. PDF to flipbook with ease