MELSERVO-J4

Servo Amplifiers

Servo Motor Connection Example (Rotary Servo Motor) Semi Closed Loop Control System with MR-J4-GF/MR-J4-B/MR-J4-A For HG-KR/HG-MR series ●●

GF B A

Servo Amplifiers Rotary Servo Motors Linear Servo Motors Direct Drive Motors Options/Peripheral Equipment Product List LVS/Wires Cautions

Servo amplifier MR-J4-GF MR-J4-B/MR-J4-B1 MR-J4-A/MR-J4-A1

Rotary servo motor

CNP3

W V U 2 3

W V U

M

1 2 4 1

(Note 3)

24 V DC for the electromagnetic brake (Note 5)

B1 B2

(Note 3)

(Note 7)

B

RA

U

(Note 2) Electromagnetic brake

Contact must be open by an external emergency stop switch.

Contact must be open when the ALM (Malfunction) or the MBR (Electromagnetic brake interlock) turns off.

CN2

(Note 1)

Plate SD BAT MRR 4 9 3 MR 2 LG P5 1

LG P5

Encoder

(Note 6)

SD BAT MRR MR

For HG-SR/HG-JR (9 kW or smaller) series ●●

Servo amplifier MR-J4-GF/MR-J4-GF4 MR-J4-B/MR-J4-B4 MR-J4-A/MR-J4-A4 Drive unit MR-J4-DU_B/MR-J4-DU_B4

Rotary servo motor

(Note 4)

W V U

W V U

A B C D

M

(Note 3)

24 V DC for the electromagnetic brake (Note 5)

B1 B2

1 2

(Note 3)

(Note 7)

B

RA

U

(Note 2) Electromagnetic brake

Contact must be open by an external emergency stop switch.

Contact must be open when the ALM (Malfunction) or the MBR (Electromagnetic brake interlock) turns off.

CN2

(Note 1)

Plate SD BAT MRR 4 9 3 MR 2 LG P5 1

LG P5

Encoder

(Note 6)

SD BAT MRR MR

Notes: 1. The signals shown are applicable when using a two-wire type encoder cable. Four-wire type is also compatible. 2. This is for the servo motor with electromagnetic brake. The electromagnetic brake terminals (B1, B2) do not have polarity. 3. Connect the grounding wire to the cabinet protective earth (PE) terminal via the servo amplifier protective earth (PE) terminal for grounding. 4. Connector or terminal varies depending on the servo amplifier capacities. Refer to the dimensions of the relevant servo amplifier in this catalog for details. 5. Do not use the 24 V DC interface power supply for the electromagnetic brake. Provide a dedicated power supply to the electromagnetic brake. 6. Encoder cable is available as an option. Refer to "Servo Motor Instruction Manual (Vol. 3)" when fabricating the cables. 7. Be sure to install a surge absorber between B1 and B2.

Be sure to read through Instruction Manual for the actual wiring and use. Use the equipment after you have a full knowledge of the equipment, safety information and instructions.