MELSERVO-J4
Options/Peripheral Equipment
Regenerative Option
GF-RJ GF
B
B-RJ
WB
A
A-RJ
Servo Amplifiers Rotary Servo Motors Linear Servo Motors Direct Drive Motors Options/Peripheral Equipment Product List LVS/Wires Cautions
Dimensions
Connections
[Unit: mm]
MR-RB30, MR-RB3N, MR-RB31, MR-RB32, MR-RB34 (for 200 V) MR-RB3M-4, MR-RB3G-4, MR-RB34-4, MR-RB3U-4 (for 400 V)
For MR-J4-500GF/B/A or smaller, MR-J4-350GF4/B4/A4 or smaller, and MR-J4W_-B
Cooling fan mounting screw (2-M4 screw) (Note 2, 3)
8.5 125 8.5
Terminal arrangement
P C
150
142
82.5
G3 G4
Disconnect P+ and D.
Servo amplifier
G4 G3 C P
30
Regenerative option
Terminal screw size: M4 Mounting screw size: M6
7
101.5
82.5
A
318
90 100
10
P C
P+
B
Variable dimensions Mass [kg] A B
D C
Cooling fan intake (Note 2, 3)
Model
G3 G4
(Note 1)
(Note 4)
MR-RB30 MR-RB3N MR-RB31 MR-RB32 MR-RB34 MR-RB3M-4 MR-RB3G-4 MR-RB34-4 MR-RB3U-4
(30)
5 m or shorter
17 335
Cooling fan (Note 2, 3)
79
2.9
23 341
MR-RB50, MR-RB5N, MR-RB51 (for 200 V) MR-RB5G-4, MR-RB54-4, MR-RB5U-4 (for 400 V)
For MR-J4-500GF4/B4/A4 and MR-J4-700GF(4)/B(4)/A(4)
Cooling fan mounting screw (2-M3 screw) (Note 2) provided on the opposite side
49
82.5
162.5 12.5 12.5 162.5 12
Terminal arrangement
P C
7 ✕ 14 slotted hole
Disconnect the wires for the built-in regenerative resistor (P+ and C).
Servo amplifier
G3 G4
Regenerative option
Cooling fan intake (Note 2)
P C
P+
82.5
350
Terminal screw size: M4 Mounting screw size: M6
C
Built-in regenerative resistor
G3 G4
Variable dimensions Mass [kg] A B
133
(Note 4)
(Note 1)
Model
(30)
7 120 8
A
2.3
200
B
5 m or shorter
MR-RB50 MR-RB5N MR-RB51 MR-RB5G-4 MR-RB54-4 MR-RB5U-4
Cooling fan (Note 2, 3)
17 217
5.6
23 223
Notes: 1. Create a sequence circuit that turns off the magnetic contactor when abnormal overheating occurs. 2. When using MR-RB3M-4, MR-RB3G-4, MR-RB34-4, MR-RB3U-4, MR-RB50, MR-RB5N, MR-RB51, MR-RB5G-4, MR-RB54-4, or MR-RB5U-4, cool the unit forcibly with a cooling fan (92 mm × 92 mm, minimum air flow: 1.0 m 3 /min). The cooling fan must be prepared by user. 3. When MR-RB30, MR-RB3N, MR-RB31, MR-RB32, or MR-RB34 is used, it may be necessary to cool the unit forcibly with a cooling fan (92 mm × 92 mm, minimum air flow: 1.0 m 3 /min), depending on the operating environment. Refer to relevant Servo Amplifier Instruction Manual for details. The cooling fan must be prepared by user. 4. G3 and G4 terminals are thermal sensor. G3-G4 opens when the regenerative option overheats abnormally.
5-62