MELSERVO-J4

Options/Peripheral Equipment

Regenerative Option 200 V/100 V

GF-RJ GF

B

B-RJ

WB

A

A-RJ

Permissible regenerative power [W] (Note 3)

External regenerative

Regenerative option

resistor (standard accessory) (Note 5)

Servo amplifier model

Built-in regenerative resistor

GRZG400-

MR-RB

5N (Note 1)

51 (Note 1)

5R (Note 2)

9F (Note 2)

9T (Note 2)

0.8 Ω 5 4 (Note 2)

0.6 Ω 5 5 (Note 2)

0.5 Ω 5 5 (Note 2)

032 12 30 3N 31 32 50 (Note 1) 14 34 40 Ω 40 Ω 13 Ω 9 Ω 6.7 Ω 40 Ω 13 Ω 9 Ω 6.7 Ω 3.2 Ω 3 Ω 2.5 Ω 26 Ω 26 Ω

MR-J4-10GF/B/A MR-J4-10B1/A1 MR-J4-20GF/B/A MR-J4-20B1/A1 MR-J4-40GF/B/A MR-J4-40B1/A1

-

-

-

-

30 -

-

-

-

-

-

-

-

-

-

-

-

-

10

-

-

-

30 100 -

-

-

-

-

-

-

-

-

-

-

-

10

- - - - - - - -

- - - - - - - -

- - - - - - - - -

30 100 - 30 100 - 30 100 - 30 100 -

- - - -

- - - - -

- -

- -

- - - -

- - - - -

- - - - - -

- - - - - - - -

- - - - - - - - -

- - - - - - - - -

- - - - - - - - -

MR-J4-60GF/B/A 10 MR-J4-70GF/B/A 20 MR-J4-100GF/B/A 20 MR-J4-200GF/B/A 100 MR-J4-350GF/B/A 100 MR-J4-500GF/B/A 130 MR-J4-700GF/B/A 170 MR-J4-11KGF/B/A -

300 - 300 -

- - - - - - - - - - - - -

- - - - - - - - - - - - -

300 -

- -

500 -

- - - -

300 -

- - - -

500 -

- - -

300 - 300 -

- - -

500 - 500 -

500 (800) -

500 (800) -

-

-

-

850 (1300)

850 (1300)

MR-J4-15KGF/B/A -

-

-

-

-

-

-

-

-

-

-

-

-

-

850 (1300)

850 (1300)

MR-J4-22KGF/B/A -

- - - - - - -

- - - - - - -

- - - - - - -

- - -

- - -

- - - - - - -

- - - - - - -

- - - - - - -

- - - - - - -

- - - - - - -

- - - - - - -

-

-

MR-J4W2-22B MR-J4W2-44B

20 20

- - - - - -

- - - - - -

100 - 100 -

MR-J4W2-77B 100 MR-J4W2-1010B 100 MR-J4W3-222B 30 MR-J4W3-444B 30

300 - 300 -

- -

- -

- -

- -

100 300 100 300

Permissible regenerative power [W] of regenerative option (Note 3) MR-RB139 MR-RB137 1.3 Ω 1.3 Ω (Note 4)

Resistance regeneration converter unit model

Drive unit model

MR-J4-DU30KB/A MR-J4-DU37KB/A

MR-CR55K 3900 Notes: 1. Be sure to cool the unit forcibly with a cooling fan (92 mm × 92 mm, minimum air flow: 1.0 m 3 /min). The cooling fan must be prepared by user. 2. The value in brackets is applicable when cooling fans (two units of 92 mm × 92 mm, minimum air flow: 1.0 m 3 /min) are installed, and then [Pr. PA02] is changed. 3. The power values in this table are resistor-generated powers, not rated powers. 4. This is the resultant resistance when three units of MR-RB137 are connected in parallel. 5. The regenerative resistor enclosed with the servo amplifiers 11 kW to 22 kW does not have a protective cover, and touching the resistor (including the wiring screws) may cause a burn or an electric shock. Provide safety measures such as a protective cover or use MR-RB_ regenerative option. * Cautions when connecting the regenerative option 1. The regenerative option causes a temperature rise of 100 °C or higher relative to the ambient temperature. Fully examine heat dissipation, installation position, wires used before installing the unit. Use flame-retardant wires or apply flame retardant on wires, and keep the wires clear of the unit. 2. Use twisted wires for connecting the regenerative option to the servo amplifier, and keep the wire length to a maximum of 5 m. 3. Use twisted wires for connecting a thermal sensor, and make sure that the sensor does not fail to work properly due to inducted noise. 1300