MELSERVO-J4
Options/Peripheral Equipment
Cables and Connectors for Servo Amplifiers Refer to "Details of Option Connectors" in this catalog for the detailed models. Item Model
Servo Amplifiers Rotary Servo Motors Linear Servo Motors Direct Drive Motors Options/Peripheral Equipment Product List LVS/Wires Cautions
Cable length
IP rating
Application
Description
For CN4 on power regeneration converter unit and CN40A on drive unit (23) Protection coordination cable MR-CUL06M
Power regeneration converter unit connector Drive unit connector
0.6 m - For MR-J4-DU_B_(-RJ)/ MR-CV_
Power regeneration converter unit connector Drive unit connector
(24) Connector set
MR-J2CN1-A
-
- For MR-J4-DU_B_(-RJ)/ MR-CV_
For CN24 on power regeneration converter unit
Power regeneration converter unit connector
(25) Connector set (Note 1)
MR-CVCN24S
-
-
-
Power regeneration converter unit connector
For CN23 on power regeneration converter unit (26) Magnetic contactor wiring connector (Standard accessory)
-
- For MR-CV_
Open tool
For power regeneration converter unit and drive unit (27) Bus bar (Note 2)
Refer to "Bus Bar" in this catalog for details.
-
-
-
-
or
(28) Adjustment bar (Note 3) MR-DCBAR035-B05
-
-
-
Resistance regeneration converter unit connector Drive unit connector Resistance regeneration converter unit connector Drive unit connector Resistance regeneration converter unit connector Drive unit connector
For CN40 on resistance regeneration converter unit and CN40A on drive unit
MR-J3CDL05M
0.5 m -
For MR-J4-DU30KB_ or larger/ MR-J4-DU30KA_ or larger/ MR-CR55K_
(29) Protection coordination cable
MR-CUL06M
0.6 m -
For MR-J4-DU30KB_ or larger/ MR-J4-DU30KA_ or larger/ MR-CR55K_
(30) Connector set
MR-J2CN1-A
-
-
For CN1 on resistance regeneration converter unit
Resistance regeneration converter unit connector
(31) Digital input/output connector
(Standard accessory)
-
- For MR-CR55K_
For CNP1 on resistance regeneration converter unit (32) Magnetic contactor wiring connector (Standard accessory)
Resistance regeneration converter unit connector
-
- For MR-CR55K_
For MR-J4-DU30KB or larger/ MR-J4-DU30KA or larger/ MR-J4-DU45KB4 or larger/ MR-J4-DU45KA4 or larger/ MR-CR55K_
For resistance regeneration converter unit and drive unit
(Standard accessory)
-
-
(33) Bus bar
or
(Standard accessory) For MR-J4-DU30KB4/ MR-J4-DU37KB4/ MR-J4-DU30KA4/ MR-J4-DU37KA4/ MR-CR55K4 Notes: 1. A crimping tool (357J-22733) manufactured by DDK Ltd. is required. Contact the manufacturer directly. 2. The bus bar varies depending on the combination of the power regeneration converter unit and the drive unit. Refer to "Bus Bar" in this catalog for details. 3. The adjustment bar is required when the total number of MR-J4-DU900B(4)(-RJ) and MR-J4-DU11KB(4)(-RJ) drive units connected to the power regeneration converter unit is even because there is a gap between the bus bar and TE2 terminal block of the final drive unit axis (right end). Place the adjustment bars in the gap and tighten the screws. - -
5-40
Made with FlippingBook Annual report maker