MELSERVO-J4

Options/Peripheral Equipment

Cables and Connectors for Servo Amplifiers Refer to "Details of Option Connectors" in this catalog for the detailed models. Item Model

Cable length

IP rating

Application

Description

For MR-J4-100GF(-RJ) or smaller/ MR-J4-100B(-RJ) or smaller/ MR-J4-40B1(-RJ) or smaller/ MR-J4-100A(-RJ) or smaller/ MR-J4-40A1(-RJ) or smaller For MR-J4-200GF(-RJ)/ MR-J4-200B(-RJ)/ MR-J4-200A(-RJ)/ MR-J4-350GF(-RJ)/ MR-J4-350B(-RJ)/ MR-J4-350A(-RJ) For MR-J4-350GF4(-RJ) or smaller/ MR-J4-350B4(-RJ) or smaller/ MR-J4-350A4(-RJ) or smaller

CNP1 connector

CNP2 connector

CNP3 connector

Open tool

Applicable wire size (Note 2) : AWG 18 to 14 Insulator OD: 3.9 mm or smaller

For CNP1/CNP2/CNP3

CNP1 connector

CNP2 connector

CNP3 connector

Open tool

Servo amplifier power connector set (Note 1) (insertion type)

(1)

(Standard accessory)

-

-

CNP1/CNP3 connector Applicable wire size (Note 2) : AWG 16 to 10 Insulator OD: 4.7 mm or smaller CNP2 connector Applicable wire size (Note 2) : AWG 18 to 14 Insulator OD: 3.9 mm or smaller

CNP1 connector

CNP2 connector

CNP3 connector

Open tool

Applicable wire size (Note 2) : AWG 16 to 14 Insulator OD: 3.9 mm or smaller

CNP1 connector

Applicable wire size (Note 2) : AWG 16 to 14 Insulator OD: 4.2 mm or smaller

For CNP1/CNP2/CNP3_

CNP2 connector

Servo amplifier power connector set (Note 3) (insertion type)

(2)

(Standard accessory)

-

- For MR-J4W2-_B/ MR-J4W3-_B

Applicable wire size (Note 2) : AWG 16 to 14 Insulator OD: 3.8 mm or smaller

CNP3A/CNP3B/CNP3C connector

Open tool

Applicable wire size (Note 2) : AWG 18 to 14 Insulator OD: 3.8 mm or smaller

Power connector

For CNP1 (3) Servo amplifier power connector (Standard accessory)

-

- For MR-J4W2-0303B6

Wire size: 0.2 mm 2 to 1.5 mm 2 (AWG 24 to 16) Insulator OD: 2.9 mm or smaller

Power connector

(4) Servo amplifier power connector (Standard accessory)

-

- For MR-J4-03A6(-RJ)

Wire size: 0.2 mm 2 to 1.5 mm 2 (AWG 24 to 16) Insulator OD: 2.9 mm or smaller

Notes: 1. This connector set is not required for 5 kW or larger servo amplifiers because terminal blocks are mounted. Refer to servo amplifier dimensions in this catalog for details. 2. The wire size shows wiring specification of the connector. Refer to "Selection Example in HIV Wires for Servo Motors" in this catalog for examples of wire size selection. 3. Press bonding type is also available. Refer to "MR-J4W2-_B MR-J4W3-_B MR-J4W2-0303B6 Servo Amplifier Instruction Manual" for details.

5-37