MELSERVO-J4
Linear Servo Motors
LM-U2 Series Primary Side (Coil) Dimensions (Note 1, 2) LM-U2PAB-05M-0SS0 ●● LM-U2PAD-10M-0SS0 ●●
LM-U2PAF-15M-0SS0 ●●
L M (cumulative pitch error: ±0.3) 60±0.3
5±0.3
(5)
B-M4 screw depth 7 (for primary-side mounting)
3 (3)
Wire mark
18.5±0.2
Power lead wire (U, V, and W): black, Grounding lead wire (E): green/yellow Effective length: 400 mm, Round crimp terminal (0.5-4)
Thermistor lead wire (G1, G2): black 2 wires-AWG 26 (standard OD: 1.58 mm) Effective length: 400 mm, Round crimp terminal (0.5-4)
0.45±0.1
24.5
(0.45)
C0.5
C0.5
1
15
25
210±10
Secondary side
400 + 40 0
66.5
[Unit: mm]
51.5
78±0.1
(Effective lead wire length)
(62)
Variable dimensions
Power/grounding lead wire Size Standard OD
Model
6.4 (0.8) (8.7)
L
M
B
(0.8)
LM-U2PAB-05M-0SS0 130 2 × 60 = 120 2 × 3 LM-U2PAD-10M-0SS0 250 4 × 60 = 240 2 × 5 LM-U2PAF-15M-0SS0 370 6 × 60 = 360 2 × 7
(8.7)
AWG 26
1.58
(25.4)
LM-U2PBB-07M-1SS0 ●●
LM-U2PBD-15M-1SS0 ●●
LM-U2PBF-22M-1SS0 ●●
M (cumulative pitch error: ±0.3) L
5±0.3
(5)
60±0.3
B-M4 screw depth 7 (for primary-side mounting)
3 (3)
18.5±0.2
Wire mark
Thermistor lead wire (G1, G2): black 2 wires-AWG 26 (standard OD: 1.58 mm) Effective length: 400 mm, Round crimp terminal (0.5-4) Power lead wire (U, V, and W): black, Grounding lead wire (E): green/yellow Effective length: 400 mm, Round crimp terminal (0.5-4)
(0.45)
24.5
0.45±0.1
C0.5
C0.5
1
15
25 210±10
(Effective lead wire length) 400 + 40 0
86.5
Secondary side
71.5
98±0.1
(82)
[Unit: mm]
Variable dimensions
Power/grounding lead wire Size Standard OD
Model
6.4 (0.9) (8.6)
L
M
B
(0.9) (8.6)
LM-U2PBB-07M-1SS0 130 2 × 60 = 120 2 × 3 LM-U2PBD-15M-1SS0 250 4 × 60 = 240 2 × 5 LM-U2PBF-22M-1SS0 370 6 × 60 = 360 2 × 7
AWG 26
1.58
(25.4)
LM-U2P2B-40M-2SS0 ●●
LM-U2P2C-60M-2SS0 ●●
LM-U2P2D-80M-2SS0 ●●
M (cumulative pitch error: ±0.3) L
(23)
23±0.3
60±0.3
B-M6 screw depth 8 (for primary-side mounting)
Power lead wire (U, V, and W): black, Grounding lead wire (E): green/yellow Effective length: 400 mm, Round crimp terminal (LM-U2P2B-40M-2SS0: 1.25-4)
5.5 (5.5)
(LM-U2P2C-60M-2SS0: 2-4) (LM-U2P2D-80M-2SS0: 2-4)
38±0.2
(0.9) C0.5
(0.9)
Wire mark
49
C0.5
22
1
50
210±10
Secondary side
(Effective lead wire length) 400 +40 0
123
83.5
138±0.1 (115)
Thermistor lead wire (G1, G2): black 2 wires-AWG 24 (standard OD: 1.74 mm) Effective length: 400 mm, Round crimp terminal (1.25-4)
[Unit: mm]
(17.5)
Variable dimensions
Power/grounding lead wire Size Standard OD
(1.1) (18.3)
(1.1)
Model
L
M
B
(18.3)
12
LM-U2P2B-40M-2SS0 286 4 × 60 = 240 2 × 5 AWG 16 LM-U2P2C-60M-2SS0 406 6 × 60 = 360 2 × 7 AWG 14 LM-U2P2D-80M-2SS0 526 8 × 60 = 480 2 × 9
2.7
(50.8)
3.12
Notes: 1. Power, grounding and thermistor lead wires do not have a long bending life. Fix the lead wires led from the primary side (coil) to a moving part to prevent the lead wires from repetitive bending. 2. Minimum bending radius of the lead wire equals to six times the standard overall diameter of the lead wire.
3-21