MELSERVO-J4

Linear Servo Motors

LM-F Series Specifications

P5H-60M 1SS0 (Note 3) S50-480 1SS0 (Note 3) S50-576 1SS0 (Note 3)

P2D-12M 1SS0

P2F-18M 1SS0

P4B-12M 1SS0

P4D-24M 1SS0

P4F-36M 1SS0

P4H-48M 1SS0

Primary side (coil)

LM-F P2B-06M- 1SS0

Linear servo motor model

Secondary side (magnet)

S20-480-1SS0 S20-576-1SS0

S40-480-1SS0 S40-576-1SS0

LM-F

Compatible servo amplifier model

MR-J4- Refer to "Combinations of Linear Servo Motor and Servo Amplifier" on p. 3-5 in this catalog.

Power supply capacity

[kVA]

3.5

7.5

10

7.5

10

14

18

22

Cooling method

Natural cooling or liquid cooling

Continuous (natural cooling) (Note 4) Continuous (liquid cooling) (Note 4)

[N] [N]

300 600

600

900

600

1200 1800 2400 3000

Thrust

1200 1800 1200 2400 3600 4800 6000 [N] 1800 3600 5400 3600 7200 10800 14400 18000

Maximum

Maximum speed (Note 1) Magnetic attraction force

[m/s]

2.0

[N] 4500 9000 13500 9000 18000 27000 36000 45000

Natural cooling Liquid cooling

[A] [A] [A]

4.0 7.8 30 348 671

7.8 16 58 264

12 23 87

7.8 17 57 393 366

15 31

21 44

28 59

22 45

Rated current

Maximum current Regenerative braking frequency (Note 2)

109 169 224

159 577 859

212 715

157

Natural cooling [times/min] Liquid cooling [times/min]

318

4230

MR-J4

396 No limit

1050 No limit

Recommended load to motor mass ratio

Maximum of 15 times the mass of the linear servo motor primary side

Thermistor

Built-in 155 (F)

Insulation class

Structure

Open (IP rating: IP00)

Ambient temperature Ambient humidity

Operation: 0 °C to 40 °C (non-freezing), storage: -15 °C to 70 °C (non-freezing) Operation: 10 %RH to 80 %RH (non-condensing), storage: 10 %RH to 90 %RH (non-condensing) Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust

Environment

Ambience

Altitude

1000 m or less above sea level

Vibration resistance

49 m/s 2

Compliance with global standards

Refer to "Compliance with Global Standards and Regulations" on p. 55 in this catalog.

Primary side (coil)

[kg]

9.0

18

27

14

28

42

56

67

480 mm/ pc: 20 576 mm/ pc: 24

Mass

Secondary side (magnet)

480 mm/pc: 7.0 576 mm/pc: 9.0

480 mm/pc: 12 576 mm/pc: 15

[kg]

Notes: 1. The maximum speed of the linear servo motor or the rated speed of the linear encoder, whichever is smaller, is the upper limit of the linear servo motor speed. 2. The regenerative braking frequency shows the permissible frequency when the linear servo motor, without a load and a regenerative option, decelerates from the maximum speed to a stop. When a load is connected; however, the value will be the table value/(m+1), where m = Mass of load/Mass of motor primary side (coil). Take measures to keep the regenerative power [W] during operation below the permissible regenerative power [W]. Use caution, especially when the operating speed changes frequently or when the regeneration is constant (as with vertical feeds). Select the most suitable regenerative option for your system with our capacity selection software. Refer to "Regenerative Option" in this catalog for the permissible regenerative power [W] when regenerative option is used. 3. Use a 400 V AC type servo amplifier for this linear servo motor. 4. Use the linear servo motor with 70% or less of the effective load ratio when it is in the servo lock state or in a small reciprocating motion.

3-9

Made with FlippingBook Annual report maker