MELSERVO-J4
Linear Servo Motors
LM-F Series Specifications
P5H-60M 1SS0 (Note 3) S50-480 1SS0 (Note 3) S50-576 1SS0 (Note 3)
P2D-12M 1SS0
P2F-18M 1SS0
P4B-12M 1SS0
P4D-24M 1SS0
P4F-36M 1SS0
P4H-48M 1SS0
Primary side (coil)
LM-F P2B-06M- 1SS0
Linear servo motor model
Secondary side (magnet)
S20-480-1SS0 S20-576-1SS0
S40-480-1SS0 S40-576-1SS0
LM-F
Compatible servo amplifier model
MR-J4- Refer to "Combinations of Linear Servo Motor and Servo Amplifier" on p. 3-5 in this catalog.
Power supply capacity
[kVA]
3.5
7.5
10
7.5
10
14
18
22
Cooling method
Natural cooling or liquid cooling
Continuous (natural cooling) (Note 4) Continuous (liquid cooling) (Note 4)
[N] [N]
300 600
600
900
600
1200 1800 2400 3000
Thrust
1200 1800 1200 2400 3600 4800 6000 [N] 1800 3600 5400 3600 7200 10800 14400 18000
Maximum
Maximum speed (Note 1) Magnetic attraction force
[m/s]
2.0
[N] 4500 9000 13500 9000 18000 27000 36000 45000
Natural cooling Liquid cooling
[A] [A] [A]
4.0 7.8 30 348 671
7.8 16 58 264
12 23 87
7.8 17 57 393 366
15 31
21 44
28 59
22 45
Rated current
Maximum current Regenerative braking frequency (Note 2)
109 169 224
159 577 859
212 715
157
Natural cooling [times/min] Liquid cooling [times/min]
318
4230
MR-J4
396 No limit
1050 No limit
Recommended load to motor mass ratio
Maximum of 15 times the mass of the linear servo motor primary side
Thermistor
Built-in 155 (F)
Insulation class
Structure
Open (IP rating: IP00)
Ambient temperature Ambient humidity
Operation: 0 °C to 40 °C (non-freezing), storage: -15 °C to 70 °C (non-freezing) Operation: 10 %RH to 80 %RH (non-condensing), storage: 10 %RH to 90 %RH (non-condensing) Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Environment
Ambience
Altitude
1000 m or less above sea level
Vibration resistance
49 m/s 2
Compliance with global standards
Refer to "Compliance with Global Standards and Regulations" on p. 55 in this catalog.
Primary side (coil)
[kg]
9.0
18
27
14
28
42
56
67
480 mm/ pc: 20 576 mm/ pc: 24
Mass
Secondary side (magnet)
480 mm/pc: 7.0 576 mm/pc: 9.0
480 mm/pc: 12 576 mm/pc: 15
[kg]
Notes: 1. The maximum speed of the linear servo motor or the rated speed of the linear encoder, whichever is smaller, is the upper limit of the linear servo motor speed. 2. The regenerative braking frequency shows the permissible frequency when the linear servo motor, without a load and a regenerative option, decelerates from the maximum speed to a stop. When a load is connected; however, the value will be the table value/(m+1), where m = Mass of load/Mass of motor primary side (coil). Take measures to keep the regenerative power [W] during operation below the permissible regenerative power [W]. Use caution, especially when the operating speed changes frequently or when the regeneration is constant (as with vertical feeds). Select the most suitable regenerative option for your system with our capacity selection software. Refer to "Regenerative Option" in this catalog for the permissible regenerative power [W] when regenerative option is used. 3. Use a 400 V AC type servo amplifier for this linear servo motor. 4. Use the linear servo motor with 70% or less of the effective load ratio when it is in the servo lock state or in a small reciprocating motion.