MELSERVO-J4
Servo Amplifiers
Panel Cut Dimensions for Power Regeneration Converter Unit and Drive unit
B B-RJ
For MR-CV11K(4) and MR-CV18K(4)
For MR-CV30K(4), MR-CV37K(4), MR-CV45K(4), MR-CV55K(4), and MR-CV75K4
W1 W4
W6
W1
W6 W9
(W5)
(W10) (W8)
(W10) (W8)
(W5)
W5
W10
W5
W10
W7 ± 0.5 W9
W2 ± 0.5 W4
(W3)
W3
W8
W3
W8
(W3)
W7 ± 0.5
360 ± 0.5 10 (10) 342 19 (19)
342 19 (19)
360 ± 0.5 10 (10)
360 ± 0.5 10 (10) 342 19 (19)
342 19 (19)
360 ± 0.5 10 (10)
Power regeneration converter unit
Power regeneration converter unit
Drive unit
Drive unit
Hole
Hole
Hole
Hole
380
380
4-M5 screw
4-M5 screw
2-M5 screw
4-M5 screw
Variable dimensions
Power regeneration converter unit
W1 90 150 300
W2
W3 45 45 60
W4 82 142 282
W5
MR-CV11K(4), MR-CV18K(4)
-
4 4 9
MR-CV30K(4), MR-CV37K(4), MR-CV45K(4)
60
MR-CV55K(4), MR-CV75K4
180
Variable dimensions
Drive unit
W6 150 240
W7 60 120
W8 45 60
W9 142 222
W10
MR-J4-DU900B(4)(-RJ), MR-J4-DU11KB(4)(-RJ) MR-J4-DU15KB(4)(-RJ), MR-J4-DU22KB(4)(-RJ)
4 9
[Unit: mm]