Honeywell Catalog
Fire Alarm Zipcord, Riser Rated
Applications: Wiring of Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Plenums. Features: Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools. One Conductor Ribbed for Polarity. Sequential Footage Markings.
Copper Conductors, Polyvinyl-Chloride Insulation. Standard Colors: White, Blue, Red.
Construction:
ARTICLE 760
FIRE ALARM ZIPCORD, RISER RATED 75˚ C NOM.
NOM. CAP.
AVG.WT.
AWG #/COND. SOL
O.D.
PF/FT
LISTINGS
PER MFT PART#
18 16 14 12
2 SOL. .088 x .196 17 FPLR/CL2R, C(UL), FT4 18 (LBS.) 2 SOL. .094 x .200 17 FPLR/CL2R, C(UL), FT4 26 (LBS.) 2 SOL. .107 x .220 17 FPLR/CL2R, C(UL), FT4 37 (LBS.) 2 SOL. .124 x .250 17 FPLR/CL2R, C(UL), FT4 52 (LBS.)
4422 4423
4424 + 4425 +
+Spools Only
Fire Alarm Mid Cap Unshielded, Riser Rated
Applications: Wiring of Mid-Capacitance Addressable Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Plenums. Features: Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools. Sequential Footage Markings. Construction: Copper Conductors, Polypropylene Insulation, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red, Conductor Color Code Chart 4.
FIRE ALARM MID CAP UNSHIELDED, RISER RATED 75˚ C NOM. NOM. CAP.
AVG.WT.
AWG #/COND.
SOL
O.D.
PF/FT
LISTINGS
PER MFT PART#
18 16 14 12
2 SOL. 2 SOL. 2 SOL. 2 SOL.
.144 .170 .208 .256
15 17 19 22
FPLR/CL2R, C(UL), FT4 19 (LBS.) FPLR/CL2R, C(UL), FT4 26 (LBS.) FPLR/CL2R, C(UL), FT4 38 (LBS.) FPLR/CL2R, C(UL), FT4 60 (LBS.)
4431
4432 + 4433 + 4434 +•
+Spools Only • Consult factory for availability.
Fire Alarm Mid Cap (Overall Shield), Riser Rated
Applications: Wiring of Mid-Capacitance Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Plenums. Features: Available in 500 foot or 1000 foot Spools. Sequential Footage Markings. Construction: Twisted Copper Conductors, Polypropylene Insulation, Aluminum/Mylar Shield with Drain Wire, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red, Conductor Color Code Chart 4.
FIRE ALARM MID CAP SHIELDED (OVERALL SHIELD) RISER RATED 75˚ C NOM. NOM. CAP.
AVG.WT.
AWG #/COND.
SOL
O.D.
PF/FT
LISTINGS
PER MFT PART#
18 16 14 12
2 SOL. 2 SOL. 2 SOL. 2 SOL.
.148 .187 .212 .260
34 38 41 48
FPLR/CL2R, C(UL), FT4 21 (LBS.) FPLR/CL2R, C(UL), FT4 32 (LBS.) FPLR/CL2R, C(UL), FT4 43 (LBS.) FPLR/CL2R, C(UL), FT4 48 (LBS.)
4441 4442
4443 •
4444
• Consult factory for availability.
35
Made with FlippingBook - professional solution for displaying marketing and sales documents online