References (continued)
CANopen machine bus (continued) (1)(7) Description Item no. Length m /ft Weight kg/ lb Connection via terminals with VW3A3628 CANopen open style module CANopen open style communication module (2) (3) Port: 1 x 5-way spring terminal block 8 – VW3A3628 – Unit reference
LXM32_CP21043
VW3A3628
CANopen line terminator for spring terminal connector
9
TCSCAR01NM120
–
–
Modicon M251 (4)
Other connection accessories and cordsets IP 20 CANopen cordsets equipped with 2 x 9-way female SUB-D connectors. Standard cable, e marking Low smoke zero halogen Flame retardant (IEC 60332-1) – 0.3/ 0.98 1.0/ 3.28
TSXCANCADD03
0.091/ 0.201 0.143/ 0.315 0.295/ 0.650 0.131/ 0.289 0.268/ 0.591
TSXCANCADD1
Altivar Solar drives
TSXCANCADD3
3.0/ 9.84 1.0/ 3.28 3.0/ 9.84
IP 20 CANopen cordsets equipped with 2 x 9-way female SUB-D connectors. Standard cable, UL certification, e marking Flame retardant (IEC 60332-2) IP 20 CANopen junction boxes equipped with: b 4 x 9-way male SUB-D connectors + screw terminal block for trunk cable tap link b Line terminator IP 20 CANopen junction boxes equipped with: b 2 screw terminal blocks for trunk cable tap link b 2 RJ45 connectors for connecting drives b 1 RJ45 connector for connecting a PC – – –
TSXCANCBDD1
CANopen machine bus (5)
8 1 (6)
TSXCANCBDD3
TSXCANTDM4
–
0.196/ 0.432
6 (6)
8 1 (6)
VW3CANTAP2
–
0.480/ 1.058
6 (6)
1 (6)
8
9
(1) The Modbus serial link always uses the RJ45 communication port. If simultaneous use of the Modbus serial link and the CANopen machine bus is required, a CANopen communication module is needed. (2) The Altivar Solar drive can only take one communication module. (3) When one of the CANopen communication modules is inserted in the Altivar Solar drive, CANopen communication via the RJ45 communication port is disabled. (4) Please refer to the Modicon M251 catalog. (5) Cable dependent on the type of controller or PLC; please refer to the corresponding catalog. (6) See page 32 for item “ 1 ” and “ 6 ”. (7) Altivar Solar products require the VW3A3600 option module adapter 1 in order to use any communication option modules.
Example of connection to the CANopen machine bus via screw terminals (with mechanical adapter 1 for the communication module 8 )
References:
Options: page 18
Combinations:
Motor starters:
Dimensions:
page 14
page 25
page 36
page 38
33
Made with FlippingBook - professional solution for displaying marketing and sales documents online