2025 QMark Digital Catalog
THZ CONTROL PANELS
RADIANT HEATERS
Models & Specifications—Contactor Panel:
ITEM INFORMATION
ELECTRICAL DATA
ENCLOSURE SIZE (H x W x D)
SUPPLY VOLTAGE
TYPE 1 "-GFI"
TYPE 3R "-3R"
TYPE 3R "-3R-GFI"
CATALOG NO.
DESCRIPTION
PHASE
TYPE 1
BR-THZ-S30-1C-0 1 DP Contactor, 30amps each, 24vac control
120–600
1
20" x 16" x 6"
24" x 16" x 6"
20" x 16" x 6"
24" x 20" x 6"
■
BR-THZ-S30-1C-1
1 DP Contactor, 30amps each, 120vac control
120–600
1
20" x 16" x 6"
24" x 16" x 6"
20" x 16" x 6"
24" x 20" x 6"
■
BR-THZ-T30-1C-0 1 DP Contactor, 30amps each, 24vac control
208–600 3
20" x 16" x 6"
24" x 20" x 6"
20" x 16" x 6"
24" x 20" x 6"
■
BR-THZ-T30-1C-1
1 DP Contactor, 30amps each, 120vac control
208–600 3
20" x 16" x 6"
24" x 20" x 6"
20" x 16" x 6"
24" x 20" x 6"
■
1-Circuit Panel
BR-THZ-S30-2C-0 2 DP Contactors, 30amps each, 24vac control
120–600
1
20" x 16" x 6"
24" x 16" x 6"
20" x 16" x 6"
24" x 20" x 6"
■
BR-THZ-S30-2C-1
2 DP Contactors, 30amps each, 120vac control
120–600
1
20" x 16" x 6"
24" x 16" x 6"
20" x 16" x 6"
24" x 20" x 6"
■
BR-THZ-T30-2C-0 2 DP Contactors, 30amps each, 24vac control
208–600 3
20" x 16" x 6"
24" x 20" x 6"
20" x 16" x 6"
24" x 20" x 6"
■
BR-THZ-T30-2C-1
2 DP Contactors, 30amps each, 120vac control
208–600 3
20" x 16" x 6"
24" x 20" x 6"
20" x 16" x 6"
24" x 20" x 6"
■
2-Circuit Panel
BR-THZ-S30-5C-0 5 DP Contactors, 30amps each, 24vac control
120–600
1
24" x 16" x 6"
24" x 24" x 6"
24" x 20" x 6"
24" x 20" x6"
■
BR-THZ-S30-5C-1
5 DP Contactors, 30amps each, 120vac control
120–600
1
24" x 16" x 6"
24" x 24" x 6"
24" x 20" x 6"
24" x 20" x 6"
■
BR-THZ-T30-5C-0 5 DP Contactors, 30amps each, 24vac control
208–600 3
24" x 24" x 6"
30" x 24" x 6"
24" x 24" x 6"
30" x 24" x 8"
■
BR-THZ-T30-5C-1
5 DP Contactors, 30amps each, 120vac control
208–600 3
24" x 24" x 6"
30" x 24" x 6"
24" x 24" x 6"
30" x 24" x 8"
■
BR-THZ-T60-5C-0 5 DP Contactors, 60amps each, 24vac control
208–600 3
30" x 24" x 8"
—
30" x 24" x 8"
—
■
5-Circuit Panel
BR-THZ-T60-5C-1
5 DP Contactors, 60amps each, 120vac control
208–600 3
30" x 24" x 8"
—
30" x 24" x 8"
—
■
BR-THZ-S30-10C-0 10 DP Contactors, 30amps each, 24vac control
120–600
1
24" x 20" x 6"
30" x 24" x 6"
24" x 20" x 6"
36" x 24" x 8"
■
BR-THZ-S30-10C-1
10 DP Contactors, 30amps each, 120vac control
120–600
1
24" x 20" x 6"
30" x 24" x 6"
24" x 20" x 6"
26" x 24" x 8"
■
BR-THZ-T30-10C-0 10 DP Contactors, 30amps each, 24vac control
208–600 3
30" x 24" x 6"
36" x 24" x 6"
30" x 24" x 8"
36" x 30" x 8"
■
BR-THZ-T30-10C-1
10 DP Contactors, 30amps each, 120vac control
208–600 3
30" x 24" x 6"
36" x 24" x 6"
30" x 24" x 8"
36" x 30" x 8"
■
BR-THZ-T60-10C-0 10 DP Contactors, 60amps each, 24vac control
208–600 3
30" x 24" x 6"
—
30" x 24" x 8"
—
■
10-Circuit Panel
BR-THZ-T60-10C-1
10 DP Contactors, 60amps each, 120vac control
208–600 3
30" x 24" x 6"
—
30" x 24" x 8"
—
■
BR-THZ-S30-20C-0 20 DP Contactors, 30amps each, 24vac control
120–600
1
36" x 24" x 6"
—
36" x 24" x 8"
—
■
BR-THZ-S30-20C-1
20 DP Contactors, 30amps each, 120vac control
120–600
1
36" x 24" x 6"
—
36" x 24" x 8"
—
■
BR-THZ-T30-20C-0 20 DP Contactors, 30amps each, 24vac control
208–600 3
36" x 36" x 6"
—
36" x 30" x 8"
—
■
BR-THZ-T30-20C-1
20 DP Contactors, 30amps each, 120vac control
208–600 3
36" x 30" x 6"
—
36" x 30" x 8"
x
■
BR-THZ-T60-20C-0 20 DP Contactors, 60amps each, 24vac control
208–600 3
36" x 30" x 6"
—
36" x 30" x 8"
x
■
20-Circuit Panel
BR-THZ-T60-20C-1
20 DP Contactors, 60amps each, 120vac control
208–600 3
36" x 30" x 6"
—
36" x 30" x 8"
—
■
SKU Legend: ◆ = Popular Products ● = Extended Offering ■ = Made to Order (Contact your local Marley Sales Representative for typically associated lead times) Add "-3R" to Catalog No. to upgrade the Contactor Panel or SSR Panel to a Type 3R enclosure. Add "-GFI" to Catalog No. GFI protection to the control panel.
187 | Radiant Heaters
For more information visit MarleyMEP.com/Products/Radiant-Heaters
rev: Nov 2025
Made with FlippingBook - professional solution for displaying marketing and sales documents online