2025 QMark Digital Catalog
ADDITIONAL CONTROLS For Convector Heaters
CONVECTORS MARLEY CUSTOM CAPABILITIES
Two types of control sections are available: • Control sections are 28" long and available in 7" high and 14" high steel models, as well DBA and SHA aluminum models
• An SCR control section which may include one or combinations of Master and Slave SCR's with an SCR type thermostat, or a Control Transformer
To develop a complete catalog number, first start with the catalog number of the selected Blank Control Section. Then add slash marks to separate the catalog numbers that describe the individual controls desired. Also specify finish, heater voltage, phase 1 or 3, and control voltage. All control sections are fully custom, factory made-to-order per application and therefore, all mounting locations, incoming power locations etc, must be verified by MEP engineering. Example : CSH07BCS1/TR24/2CB3P30. This example catalog number would be for a 7-inch Commercial Style Grille Steel Convector control section with a 24v transformer relay, two 3-pole 30 amp Circuit Breakers.
Blank Control Section 1 : CATALOG NO. DESCRIPTION
Circuit Breakers 2 : CATALOG NO.
SIZE
INLET / OUTLET
DESCRIPTION
AMPERAGE VOLTAGE
DBA3BCSF
3 5/8 x 6 x 28 in.
Front Inlet
1CB2P30
(1) Three-Pole Circuit Breaker
30 Amps
Aluminum Draft Barrier Style Control Section
DBA3BCSB
3 5/8 x 6 x 28 in.
Bottom Inlet
1CB2P60
(1) Two-Pole Circuit Breaker
60 Amps
SHABCSF
5 3/8 x 7 x 28 in.
Front Inlet
1CB3P30
(1) Three-Pole Circuit Breaker
30 Amps
SHABCSB
5 3/8 x 7 x 28 in.
Bottom Inlet
1CB3P60
(1) Three-Pole Circuit Breaker
60 Amps
208, 240, 277 VAC
CSH07BCS1
7 in. High
Bottom Inlet/Top Outlet
2CB2P30
(2) Two-Pole Circuit Breaker
30 Amps
CSH14BCS1
14 in. High
Bottom Inlet/Top Outlet
2CB2P60
(2) Two-Pole Circuit Breaker
60 Amps
Steel Commercial Style Control Section
CSH14BCS3
14 in. High
Bottom Inlet/Front Outlet
2CB3P30
(2) Three-Pole Circuit Breaker
30 Amps
DSH07BCS1
7 in. High
Bottom Inlet/Top Outlet
2CB3P60
(2) Three-Pole Circuit Breaker
60 Amps
DSH14BCS1
14 in. High
Bottom Inlet/Top Outlet
DSH07BCS2
7 in. High
Front Inlet/Top Outlet
SCR Controls 2 – Lead:
Steel Decorative Style Control Section
DSH14BCS2
14 in. High
Front Inlet/Top Outlet
CATALOG NO.
DESCRIPTION
Control Transformer, 50 VA Rating:
Lead SCR Control Rated 25 Amps @120 – 480V AC. Lead units accept 0-10V DC, 4-20mA, or 135 OHM proportional control inputs. Each Lead SCR can provide low voltage signal to Follower SCR(s) 4
M90525A
CATALOG NO.
DESCRIPTION
M90548A
Lead SCR Control Rated 48 Amps @120 – 480V AC
TR24
240/208V Primary, 24V Secondary Step Down Transformer
M90548A-2
3-phase Lead SCR Control Rated 48 Amps @120 – 480V AC
TR27
277V Primary, 24V Secondary Step Down Transformer
SCR Controls 2 – Follower:
Thermostat & Receptacle:
CATALOG NO.
DESCRIPTION
CATALOG NO.
DESCRIPTION
S90525A
SCR Follower unit controller. Rated 25 Amps.
Single-Pole Pilot Duty Thermostat, 60°-120°F Temperature Range– 125 VA Rating Two-Stage Pilot Duty Thermostat, 60°-120°F Temperature Range– 125 VA Rating. Available on 2- or 3-element, single-phase heaters only. Two-Stage Thermostat 60-120°F temperature range, adjustable through outlet grille-tamper-resistant. Available on 2- or 3-element, single phase heaters only. 120V Receptacle Duplex receptacle, 120V/20A, mounting in left or right end cap of Steel Convectors only. For Alum. Convectors verify locations with factory.
1PDT
S90548A
SCR Follower unit controller. Rated 48 Amps
2PDT
SCR Thermostat 4 :
CATALOG NO.
DESCRIPTION
2ST
Provides a proportional 2–10 VDC output for controlling 0–100% of the connected load to each Lead SCR 4.
T90613V
R
NOTE: Each SCR incorporates its own zero-firing logic, providing any combination or connection arrangement for single or three phase applications. 25A single phase SCR can be mounted in the SHA aluminum convector. Each Master and Thermostat will require 24V AC Transformer. Specify holding coil voltage where applicable. On all 5 in. high steel convectors the two-pole thermostat must go in the right hand junction box (TR must mount in RH junction box. 2T+TR are invalid in 5 in. high steel convectors). (1) Blank control sections are subject to the same color selections and pricing as the appropriate matching heater. (2) Not available in DBA control sections. (4) Maximum of 8 SCRs is the limit for one thermostat output signal.
Power On/Off Switch:
CATALOG NO.
DESCRIPTION
Pilot Duty Power On/Off Switch; Double-Pole (Disconnects relay holding coil circuit)
DS
160 | Convectors
For more information visit MarleyMEP.com/Products/Convector-Heaters
rev: Nov 2025
Made with FlippingBook - professional solution for displaying marketing and sales documents online